Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,199
matching recommendationsSIC | 367 | Electronic Components And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0189 # 03 Y:1997 | 03 | 1997 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $425 | $800 | Not Implemented |
UF0189 # 04 Y:1997 | 04 | 1997 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,074 | $74,230 | Not Implemented |
UF0189 # 05 Y:1997 | 05 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $904 | $700 | Implemented |
UF0189 # 06 Y:1997 | 06 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $3,500 | $1,000 | Implemented |
UF0189 # 07 Y:1997 | 07 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $25,456 | $0 | Not Implemented |
UF0189 # 08 Y:1997 | 08 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $9,950 | $750 | Implemented |
UF0189 # 09 Y:1997 | 09 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $600,000 | $15,000 | Implemented |
UF0189 # 10 Y:1997 | 10 | 1997 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $850,769 | $87,000 | Implemented |
AS0213 # 01 Y:1997 | 01 | 1997 | INSTALL OCCUPANCY SENSORS | $286 | $450 | Not Implemented |
AS0213 # 02 Y:1997 | 02 | 1997 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $287 | $300 | Not Implemented |
AS0213 # 03 Y:1997 | 03 | 1997 | DISCONNECT BALLASTS | $277 | $15 | Not Implemented |
AS0213 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $122 | $348 | Not Implemented |
AS0213 # 05 Y:1997 | 05 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,357 | $3,800 | Not Implemented |
AS0213 # 06 Y:1997 | 06 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,642 | $1,827 | Not Implemented |
AS0213 # 07 Y:1997 | 07 | 1997 | USE EVAPORATION TO CONCENTRATE MATERIAL | $1,813 | $5,185 | Not Implemented |
AS0213 # 08 Y:1997 | 08 | 1997 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,674 | $60 | Not Implemented |
AS0213 # 09 Y:1997 | 09 | 1997 | ADOPT IN-HOUSE MATERIAL GENERATION | $1,487 | $1,020 | Not Implemented |
AS0213 # 10 Y:1997 | 10 | 1997 | INSTALL AN UNINTERUPTABLE POWER SUPPLY | $1,365,942 | $500,000 | Not Implemented |
MA0402 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $217,449 | $140,000 | Not Implemented |
MA0402 # 02 Y:1997 | 02 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $61,092 | $16,597 | Not Implemented |
MA0402 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,628 | $6,075 | Not Implemented |
MA0402 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,721 | $4,925 | Not Implemented |
MA0402 # 05 Y:1997 | 05 | 1997 | OPTIMIZE PLANT POWER FACTOR | $2,577 | $4,275 | Not Implemented |
MA0402 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,257 | $200 | Not Implemented |
SD0184 # 01 Y:1997 | 01 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,327 | $150 | Implemented |