Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,192

matching recommendations
Reset
SIC 367 Electronic Components And Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KG0065 # 04 Y:1996 04 1996 INSTALL TIMERS AND/OR THERMOSTATS $732 $300 Not Implemented
KG0065 # 05 Y:1996 05 1996 LOWER CEILING TO REDUCE CONDITIONED SPACE $427 $400 Not Implemented
KG0065 # 06 Y:1996 06 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $5,889 $3,200 Not Implemented
AS0177 # 07 Y:1996 07 1996 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,289 $8,800 Not Implemented
AS0177 # 08 Y:1996 08 1996 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,920 $0 Not Implemented
MA0368 # 01 Y:1996 01 1996 TREAT AND REUSE RINSE WATERS $17,190 $12,000 Not Implemented
MA0368 # 02 Y:1996 02 1996 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $8,710 $25,500 Not Implemented
MA0368 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,509 $11,189 Implemented
MA0368 # 04 Y:1996 04 1996 REPAIR OR REPLACE STEAM TRAPS $1,990 $868 Implemented
MA0368 # 05 Y:1996 05 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,042 $2,804 Not Implemented
MA0368 # 06 Y:1996 06 1996 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $285 $460 Implemented
AS0177 # 01 Y:1996 01 1996 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $636 $0 Not Implemented
AS0177 # 02 Y:1996 02 1996 ADD AREA LIGHTING SWITCHES $1,982 $0 Not Implemented
AS0177 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $660 $900 Not Implemented
AS0177 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,531 $13,132 Not Implemented
AS0177 # 05 Y:1996 05 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $204 $390 Not Implemented
AS0177 # 06 Y:1996 06 1996 INSULATE BARE EQUIPMENT $444 $180 Implemented
AS0175 # 01 Y:1996 01 1996 UPGRADE CONTROLS ON COMPRESSORS $3,647 $11,000 Not Implemented
AS0175 # 02 Y:1996 02 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,105 $6,800 Not Implemented
AS0175 # 03 Y:1996 03 1996 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $6,925 $6,300 Implemented
AS0175 # 04 Y:1996 04 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $27,635 $25,000 Not Implemented
AS0175 # 05 Y:1996 05 1996 INSTALL OCCUPANCY SENSORS $1,625 $1,350 Implemented
AS0175 # 06 Y:1996 06 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,214 $21,652 Implemented
AS0175 # 07 Y:1996 07 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $237 $499 Implemented
AS0175 # 08 Y:1996 08 1996 USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME $8,910 $1,200 Not Implemented