Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

367

matching recommendations
Reset
SIC 3672 Printed Circuit Boards
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0333 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $588 $800 Implemented
MA0333 # 05 Y:1995 05 1995 RECOVER WASTE HEAT FROM EQUIPMENT $412 $461 Implemented
IA0109 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,253 $20,116 Implemented
IA0109 # 03 Y:1995 03 1995 DISCONNECT BALLASTS $257 $25 Implemented
IA0109 # 04 Y:1995 04 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $813 $2,100 Implemented
SD0112 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,149 $450 Implemented
SD0112 # 02 Y:1995 02 1995 COVER OPEN TANKS $1,015 $250 Implemented
SD0112 # 03 Y:1995 03 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $1,144 $1,600 Implemented
SD0112 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,282 $563 Implemented
SD0112 # 05 Y:1995 05 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,168 $6,733 Implemented
SD0112 # 06 Y:1995 06 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $5,047 $4,305 Implemented
SD0112 # 08 Y:1995 08 1995 INSTALL TIMERS AND/OR THERMOSTATS $1,306 $849 Implemented
SD0112 # 09 Y:1995 09 1995 REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS $730 $250 Implemented
SD0112 # 11 Y:1995 11 1995 USE HIGH QUALITY SCRAP (LOW SULFUR) TO REDUCE HAZARDOUS SLUDGE GENERATION $1,069 $1,000 Implemented
OK0455 # 02 Y:1995 02 1995 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,638 $0 Implemented
OK0455 # 03 Y:1995 03 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $913 $128 Implemented
OK0455 # 07 Y:1995 07 1995 INSTALL OCCUPANCY SENSORS $467 $1,100 Implemented
OK0455 # 09 Y:1995 09 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $333 $1,186 Implemented
SF0047 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,510 $516 Implemented
SF0047 # 03 Y:1995 03 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $3,063 $1,400 Implemented
AS0137 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $697 $300 Implemented
AS0137 # 06 Y:1995 06 1995 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,608 $0 Implemented
AS0116 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $60,465 $81,258 Implemented
AS0116 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $4,022 $2,265 Implemented
AS0116 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $33,572 $18,827 Implemented