Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

605

matching recommendations
Reset
SIC 3674 Semiconductors And Related Devices
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0366 # 01 Y:1996 01 1996 RECOVER WASTE HEAT FROM EQUIPMENT $1,638 $0 Not Implemented
MA0366 # 02 Y:1996 02 1996 OPTIMIZE PLANT POWER FACTOR $11,369 $9,450 Implemented
MA0366 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $31,893 $20,255 Not Implemented
MA0366 # 04 Y:1996 04 1996 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,919 $9,000 Not Implemented
MA0366 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,474 $350 Implemented
MA0366 # 06 Y:1996 06 1996 RECOVER AND REUSE COOLING WATER $1,421 $1,471 Not Implemented
MA0366 # 07 Y:1996 07 1996 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,093 $4,910 Not Implemented
MA0366 # 08 Y:1996 08 1996 UTILIZE A LESS EXPENSIVE COOLING METHOD $435 $250 Not Implemented
SD0134 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,991 $3,350 Not Implemented
SD0134 # 02 Y:1996 02 1996 RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING $2,747 $2,500 Not Implemented
SD0134 # 03 Y:1996 03 1996 COVER OPEN TANKS $679 $161 Not Implemented
SD0134 # 04 Y:1996 04 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,979 $1,860 Not Implemented
SD0134 # 05 Y:1996 05 1996 INSTALL SPECTRAL REFLECTORS / DELAMP $3,101 $5,520 Not Implemented
SD0134 # 06 Y:1996 06 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,336 $1,100 Not Implemented
SD0134 # 07 Y:1996 07 1996 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE $878 $100 Not Implemented
SD0134 # 08 Y:1996 08 1996 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $231 $500 Not Implemented
CO0349 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,640 $54,100 Implemented
CO0349 # 02 Y:1995 02 1995 RECOVER AND REUSE COOLING WATER $18,410 $2,190 Implemented
CO0349 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,690 $7,000 Implemented
CO0349 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $3,030 $2,280 Not Implemented
CO0349 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,860 $4,470 Not Implemented
CO0349 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,690 $470 Not Implemented
CO0349 # 07 Y:1995 07 1995 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $990 $10,410 Not Implemented
SF0066 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,169 $722 Implemented
SF0066 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,319 $41,870 Not Implemented