Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
404
matching recommendationsSIC | 3674 | Semiconductors And Related Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0626 # 01 Y:2009 | 01 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $46,520 | $7,500 | Implemented |
CO0626 # 05 Y:2009 | 05 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,140 | $360 | Not Implemented |
CO0626 # 03 Y:2009 | 03 | 2009 | USE SOLAR HEAT TO MAKE ELECTRICTY | $5,100 | $45,500 | Not Implemented |
CO0626 # 06 Y:2009 | 06 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $370 | $780 | Not Implemented |
CO0626 # 02 Y:2009 | 02 | 2009 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,900 | $0 | Not Implemented |
CO0626 # 04 Y:2009 | 04 | 2009 | USE PHOTOCELL CONTROLS | $2,350 | $620 | Not Implemented |
UD0801 # 07 Y:2009 | 07 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $993 | $45,000 | Implemented |
UD0801 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,877 | $16,721 | Implemented |
UD0801 # 02 Y:2009 | 02 | 2009 | REDUCE VENTILATION AIR | $10,610 | $14,833 | Implemented |
UD0801 # 06 Y:2009 | 06 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,087 | $0 | Not Implemented |
UD0801 # 03 Y:2009 | 03 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,599 | $14,833 | Implemented |
UD0801 # 01 Y:2009 | 01 | 2009 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $18,742 | $14,833 | Implemented |
UD0801 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,100 | $14,833 | Implemented |
UD0801 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $62 | $0 | Not Implemented |
MA0640 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,895 | $3,000 | Implemented |
MA0640 # 02 Y:2008 | 02 | 2008 | OPTIMIZE PLANT POWER FACTOR | $11,811 | $11,850 | Implemented |
MA0640 # 04 Y:2008 | 04 | 2008 | MINIMIZE WATER USAGE | $4,210 | $18,000 | Not Implemented |
MA0640 # 03 Y:2008 | 03 | 2008 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $11,640 | $43,000 | Not Implemented |
MA0640 # 07 Y:2008 | 07 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $644 | $689 | Implemented |
MA0640 # 01 Y:2008 | 01 | 2008 | REDUCE VENTILATION AIR | $36,692 | $39,000 | Implemented |
MA0640 # 06 Y:2008 | 06 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $977 | $0 | Implemented |
LE0254 # 01 Y:2007 | 01 | 2007 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $81,900 | $65,000 | Not Implemented |
LE0254 # 07 Y:2007 | 07 | 2007 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $3,029 | $800 | Not Implemented |
LE0254 # 02 Y:2007 | 02 | 2007 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $67,570 | $67,000 | Not Implemented |
LE0254 # 06 Y:2007 | 06 | 2007 | OPTIMIZE FILTRATION CLEANING / REPLACEMENT TO MINIMIZE AIR RESISTANCE | $5,988 | $3,000 | Implemented |