Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
158
matching recommendationsSIC | 3675 | Electronic Capacitors |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SU0412 # 09 Y:2016 | 09 | 2016 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $119 | $576 | Not Implemented |
SU0412 # 03 Y:2016 | 03 | 2016 | INSULATE BARE EQUIPMENT | $296 | $169 | Not Implemented |
SU0412 # 01 Y:2016 | 01 | 2016 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $154 | $0 | Not Implemented |
SU0412 # 04 Y:2016 | 04 | 2016 | INSTALL / REPAIR INSULATION ON STEAM LINES | $98 | $78 | Not Implemented |
SU0412 # 02 Y:2016 | 02 | 2016 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,342 | $480 | Not Implemented |
SU0412 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $3,474 | $3,632 | Not Implemented |
MA0699 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $706 | $100 | Implemented |
MA0699 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,627 | $104,325 | Implemented |
MA0699 # 04 Y:2012 | 04 | 2012 | ELIMINATE/REDUCE AN OPERATION | $1,855 | $500 | Not Implemented |
MA0699 # 03 Y:2012 | 03 | 2012 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $5,019 | $24,000 | Implemented |
MA0699 # 01 Y:2012 | 01 | 2012 | INSTALL TIMERS AND/OR THERMOSTATS | $25,140 | $9,900 | Implemented |
MA0699 # 05 Y:2012 | 05 | 2012 | USE HEAT PUMP FOR SPACE CONDITIONING | $1,250 | $6,500 | Implemented |
MA0627 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $6,984 | $8,550 | Implemented |
MA0627 # 06 Y:2008 | 06 | 2008 | INSTALL / REPAIR INSULATION ON STEAM LINES | $948 | $1,000 | Implemented |
MA0627 # 02 Y:2008 | 02 | 2008 | REDUCE VENTILATION AIR | $8,813 | $16,000 | Implemented |
MA0627 # 04 Y:2008 | 04 | 2008 | USE MINIMUM SAFE OVEN VENTILATION | $6,674 | $5,000 | Not Implemented |
MA0627 # 05 Y:2008 | 05 | 2008 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $1,648 | $4,300 | Not Implemented |
MA0627 # 01 Y:2008 | 01 | 2008 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $52,302 | $35,000 | Implemented |
LM0115 # 04 Y:2006 | 04 | 2006 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $55,692 | $7,875 | Not Implemented |
LM0115 # 03 Y:2006 | 03 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,573 | $0 | Not Implemented |
LM0115 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $947 | $200 | Not Implemented |
LM0115 # 01 Y:2006 | 01 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,535 | $200 | Not Implemented |
LE0228 # 01 Y:2006 | 01 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $15,075 | $41,200 | Not Implemented |
LE0228 # 07 Y:2006 | 07 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $315 | $750 | Not Implemented |
LE0228 # 08 Y:2006 | 08 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,856 | $43,904 | Not Implemented |