Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
30
matching recommendationsSIC | 3676 | Electronic Resistors |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0681 # 04 Y:2003 | 04 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,862 | $7,947 | Implemented |
UD0681 # 13 Y:2003 | 13 | 2003 | DISCONNECT BALLASTS | $159 | $46 | Implemented |
UD0681 # 12 Y:2003 | 12 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $350 | $230 | Not Implemented |
UD0681 # 11 Y:2003 | 11 | 2003 | INSULATE BARE EQUIPMENT | $930 | $1,360 | Implemented |
UD0681 # 10 Y:2003 | 10 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,095 | $91 | Not Implemented |
UD0681 # 09 Y:2003 | 09 | 2003 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,095 | $1,268 | Not Implemented |
UD0681 # 08 Y:2003 | 08 | 2003 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,740 | $0 | Implemented |
UD0681 # 07 Y:2003 | 07 | 2003 | AIR CONDITION ONLY SPACE NECESSARY | $1,800 | $0 | Implemented |
UD0681 # 06 Y:2003 | 06 | 2003 | REDUCE VENTILATION AIR | $2,785 | $1,360 | Not Implemented |
UD0681 # 05 Y:2003 | 05 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,840 | $700 | Not Implemented |
UD0681 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $13,200 | $8,060 | Not Implemented |
UD0681 # 02 Y:2003 | 02 | 2003 | MAKE ICE DURING OFF PEAK HOURS FOR COOLING | $26,822 | $100,000 | Not Implemented |
UD0681 # 01 Y:2003 | 01 | 2003 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $82,000 | $1,490 | Implemented |
UD0681 # 14 Y:2003 | 14 | 2003 | INSTALL OCCUPANCY SENSORS | $105 | $160 | Not Implemented |
WI0298 # 05 Y:1997 | 05 | 1997 | INSTALL AUTOMATIC PACKING EQUIPMENT | $24,000 | $20,000 | Implemented |
WI0298 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $29,190 | $30,000 | Implemented |
WI0298 # 02 Y:1997 | 02 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,867 | $1,480 | Not Implemented |
WI0298 # 03 Y:1997 | 03 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,444 | $120 | Implemented |
WI0298 # 04 Y:1997 | 04 | 1997 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $25,193 | $0 | Not Implemented |
WI0298 # 08 Y:1997 | 08 | 1997 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $686 | $0 | Not Implemented |
WI0298 # 06 Y:1997 | 06 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $3,119 | $18,000 | Not Implemented |
WI0298 # 07 Y:1997 | 07 | 1997 | MINIMIZE WATER USAGE | $2,100 | $1,000 | Not Implemented |
WI0298 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $140 | $0 | Not Implemented |
CO0208 # 06 Y:1991 | 06 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $800 | $1,500 | Implemented |
CO0208 # 05 Y:1991 | 05 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,100 | $200 | Implemented |