Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
70
matching recommendationsSIC | 3679 | Electronic Components, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0390 # 08 Y:2004 | 08 | 2004 | INSTALL OCCUPANCY SENSORS | $289 | $450 | Implemented |
AS0390 # 07 Y:2004 | 07 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,263 | $30 | Implemented |
AS0390 # 06 Y:2004 | 06 | 2004 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,590 | $230 | Not Implemented |
AS0390 # 05 Y:2004 | 05 | 2004 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,779 | $197 | Implemented |
AS0390 # 04 Y:2004 | 04 | 2004 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $3,384 | $15,950 | Not Implemented |
AS0390 # 03 Y:2004 | 03 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,953 | $23,750 | Not Implemented |
AS0390 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $9,783 | $400 | Implemented |
AS0390 # 01 Y:2004 | 01 | 2004 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $11,500 | $80 | Implemented |
AS0295 # 03 Y:2001 | 03 | 2001 | INSTALL OCCUPANCY SENSORS | $433 | $450 | Not Implemented |
AS0295 # 01 Y:2001 | 01 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,104 | $5,107 | Not Implemented |
AS0295 # 02 Y:2001 | 02 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $4,459 | $10,800 | Not Implemented |
AS0295 # 04 Y:2001 | 04 | 2001 | USE SYNTHETIC LUBRICANT | $826 | $694 | Not Implemented |
AS0295 # 05 Y:2001 | 05 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $152 | $60 | Not Implemented |
AS0295 # 06 Y:2001 | 06 | 2001 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $234,131 | $140,869 | Implemented |
AS0228 # 09 Y:1998 | 09 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $498,755 | $240 | Implemented |
AS0228 # 01 Y:1998 | 01 | 1998 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $244,239 | $410,200 | Implemented |
AS0228 # 02 Y:1998 | 02 | 1998 | USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT | $955,252 | $4,000,000 | Not Implemented |
AS0228 # 03 Y:1998 | 03 | 1998 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $395,073 | $1,524,052 | Not Implemented |
AS0228 # 04 Y:1998 | 04 | 1998 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $17,372 | $80,000 | Not Implemented |
AS0228 # 05 Y:1998 | 05 | 1998 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $69,699 | $225,000 | Not Implemented |
AS0228 # 07 Y:1998 | 07 | 1998 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $12,819 | $60 | Not Implemented |
AS0228 # 11 Y:1998 | 11 | 1998 | INSTALL EQUIPMENT TO MOVE PRODUCT | $11,311 | $14,500 | Not Implemented |
AS0228 # 10 Y:1998 | 10 | 1998 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $6,873 | $3,125 | Implemented |
AS0228 # 08 Y:1998 | 08 | 1998 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $65,562 | $7,000 | Not Implemented |
AS0228 # 06 Y:1998 | 06 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $768 | $60 | Not Implemented |