Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
989
matching recommendationsSIC | 369 | Misc. Electrical Equipment & Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0278 # 12 Y:1999 | 12 | 1999 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $250 | $100 | n/a |
NC0165 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,720 | $10,000 | Implemented |
NC0165 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,539 | $1,500 | Implemented |
NC0165 # 03 Y:1999 | 03 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $151,290 | $29,000 | Implemented |
NC0165 # 04 Y:1999 | 04 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $231,300 | $1,600,000 | Not Implemented |
NC0165 # 05 Y:1999 | 05 | 1999 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $824,740 | $836,000 | Implemented |
UD0576 # 01 Y:1999 | 01 | 1999 | AUTOMATE FINISHING PROCESS | $270,000 | $150,000 | Not Implemented |
UD0576 # 02 Y:1999 | 02 | 1999 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $269,087 | $365,000 | Not Implemented |
UD0576 # 03 Y:1999 | 03 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,377 | $4,700 | Implemented |
UD0576 # 04 Y:1999 | 04 | 1999 | USE PLASTIC PALLETS INSTEAD OF WOOD | $6,058 | $21,000 | Not Implemented |
UD0576 # 05 Y:1999 | 05 | 1999 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $2,325 | $9,165 | Not Implemented |
UD0576 # 06 Y:1999 | 06 | 1999 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $1,407 | $1,000 | Implemented |
GT0663 # 01 Y:1999 | 01 | 1999 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $9,639 | $0 | Not Implemented |
GT0663 # 02 Y:1999 | 02 | 1999 | COMBINE UTILITY METERS | $1,117 | $0 | Not Implemented |
GT0663 # 03 Y:1999 | 03 | 1999 | COMBINE UTILITY METERS | $7,755 | $0 | Not Implemented |
GT0663 # 04 Y:1999 | 04 | 1999 | MINIMIZE WATER USAGE | $113 | $0 | Not Implemented |
GT0663 # 05 Y:1999 | 05 | 1999 | COMBINE UTILITY METERS | $375 | $0 | Not Implemented |
GT0663 # 06 Y:1999 | 06 | 1999 | METER WASTE WATER | $980 | $400 | Not Implemented |
GT0663 # 07 Y:1999 | 07 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $19,035 | $5,000 | Not Implemented |
GT0663 # 08 Y:1999 | 08 | 1999 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $3,250 | $6,700 | Not Implemented |
GT0663 # 09 Y:1999 | 09 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $10,805 | $4,600 | Not Implemented |
GT0663 # 10 Y:1999 | 10 | 1999 | INSTALL AUTOMATIC PACKING EQUIPMENT | $10,000 | $0 | Not Implemented |
SF0166 # 01 Y:1999 | 01 | 1999 | UPGRADE CONTROLS ON COMPRESSORS | $9,418 | $350 | Not Implemented |
SF0166 # 02 Y:1999 | 02 | 1999 | INSTALL SET-BACK TIMERS | $1,497 | $510 | Not Implemented |
SF0166 # 03 Y:1999 | 03 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,970 | $11,700 | Not Implemented |