Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 369 | Misc. Electrical Equipment & Supplies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0188 # 05 Y:2001 | 05 | 2001 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $8,358 | $6,500 | Not Implemented |
MS0188 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,583 | $14,235 | Not Implemented |
MS0188 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $1,408 | $1,310 | Not Implemented |
MS0188 # 02 Y:2001 | 02 | 2001 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $62 | $88 | Not Implemented |
MS0188 # 01 Y:2001 | 01 | 2001 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $134 | $27 | Not Implemented |
MS0155 # 04 Y:2000 | 04 | 2000 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $456 | $458 | n/a |
MS0155 # 03 Y:2000 | 03 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $552 | $71 | n/a |
MS0155 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,071 | $293 | n/a |
MS0155 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,073 | $2,808 | n/a |
MS0124 # 03 Y:1998 | 03 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $740 | $400 | Implemented |
MS0124 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,313 | $15,976 | Not Implemented |
MS0124 # 05 Y:1998 | 05 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $35,438 | $25,290 | Not Implemented |
MS0124 # 04 Y:1998 | 04 | 1998 | INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE | $4,500 | $2,888 | Implemented |
MS0124 # 02 Y:1998 | 02 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,507 | $944 | Implemented |
MS0124 # 06 Y:1998 | 06 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $51 | $14 | Implemented |
MS0049 # 05 Y:1996 | 05 | 1996 | USE WATER ON AIR CONDITIONING EXCHANGER TO IMPROVE HEAT TRANSFER AND INCREASE AIR CONDITIONER EFFICIENCY | $2,389 | $5,280 | Not Implemented |
MS0049 # 07 Y:1996 | 07 | 1996 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $428,130 | $50,000 | Not Implemented |
MS0049 # 06 Y:1996 | 06 | 1996 | OPTIMIZE PLANT POWER FACTOR | $1,144 | $900 | Not Implemented |
MS0049 # 04 Y:1996 | 04 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,838 | $80 | Not Implemented |
MS0049 # 03 Y:1996 | 03 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $790 | $570 | Implemented |
MS0049 # 02 Y:1996 | 02 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,936 | $5,000 | Implemented |
MS0049 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,933 | $6,695 | Implemented |
MS0008 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $164 | $116 | Not Implemented |
MS0008 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,252 | $10,100 | Not Implemented |
MS0008 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,373 | $502 | Not Implemented |