Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

38

matching recommendations
Reset
SIC 369 Misc. Electrical Equipment & Supplies
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MZ0331 # 02 Y:2022 02 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $18,037 $46,350 Implemented
MZ0331 # 03 Y:2022 03 2022 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) $91,773 $9,040 Implemented
MZ0331 # 04 Y:2022 04 2022 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $5,985 $29,286 Implemented
MZ0331 # 05 Y:2022 05 2022 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $402,938 $1,820,000 Not Implemented
MZ0331 # 06 Y:2022 06 2022 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $31,613 $98,280 Implemented
MZ0331 # 07 Y:2022 07 2022 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM $76,144 $423,000 Not Implemented
MZ0331 # 08 Y:2022 08 2022 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $110,196 $55,220 Not Implemented
MZ0331 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $23,162 $25,757 Implemented
UL2212 # 05 Y:2022 05 2022 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $7,902 $63,000 Not Implemented
UL2212 # 04 Y:2022 04 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $34,406 $237,031 Not Implemented
UL2212 # 03 Y:2022 03 2022 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,936 $19,500 Not Implemented
UL2212 # 02 Y:2022 02 2022 INSTALL OCCUPANCY SENSORS $1,208 $2,171 Not Implemented
UL2212 # 01 Y:2022 01 2022 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,840 $16,294 Not Implemented
UC2202 # 03 Y:2022 03 2022 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $322 $960 Not Implemented
UC2202 # 05 Y:2022 05 2022 USE SOLAR HEAT TO MAKE ELECTRICTY $135,088 $543,322 Not Implemented
UC2202 # 04 Y:2022 04 2022 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,344 $200 Implemented
UC2202 # 01 Y:2022 01 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $21,740 $114,471 Implemented
UC2202 # 02 Y:2022 02 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,684 $2,000 Implemented
WV0629 # 07 Y:2022 07 2022 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $1,933 $1,500 Implemented
WV0629 # 01 Y:2022 01 2022 UPGRADE CONTROLS ON COMPRESSORS $27,447 $88,959 Not Implemented
WV0629 # 02 Y:2022 02 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $15,878 $1,254 Implemented
WV0629 # 03 Y:2022 03 2022 INSTALL OCCUPANCY SENSORS $13,895 $15,573 Implemented
WV0629 # 04 Y:2022 04 2022 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $13,444 $15,140 Implemented
WV0629 # 05 Y:2022 05 2022 TURN OFF EQUIPMENT WHEN NOT IN USE $6,486 $3,744 Implemented
WV0629 # 06 Y:2022 06 2022 DEVELOP A REPAIR/REPLACE POLICY $2,938 $1,349 Implemented