Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
136
matching recommendationsSIC | 3692 | Primary Batteries, Dry And Wet |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UA0015 # 01 Y:2008 | 01 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,437 | $20,527 | Not Implemented |
UA0015 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,846 | $35,708 | Not Implemented |
UA0015 # 03 Y:2008 | 03 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $871 | $5,926 | Not Implemented |
UA0015 # 04 Y:2008 | 04 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $204 | $0 | Implemented |
UA0015 # 05 Y:2008 | 05 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $7,573 | $823 | Implemented |
MA0624 # 01 Y:2007 | 01 | 2007 | REPAIR OR REPLACE STEAM TRAPS | $62,300 | $24,500 | Implemented |
MA0624 # 02 Y:2007 | 02 | 2007 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $47,607 | $22,000 | Not Implemented |
MA0624 # 03 Y:2007 | 03 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $24,012 | $50,000 | Implemented |
MA0624 # 04 Y:2007 | 04 | 2007 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $14,298 | $11,500 | Implemented |
MA0624 # 05 Y:2007 | 05 | 2007 | IMPROVE COMBUSTION CONTROL CAPABILITY | $12,255 | $75,000 | Implemented |
MA0624 # 06 Y:2007 | 06 | 2007 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,448 | $2,500 | Implemented |
MA0624 # 07 Y:2007 | 07 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,741 | $0 | Implemented |
MA0624 # 08 Y:2007 | 08 | 2007 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,655 | $4,000 | Implemented |
MA0624 # 09 Y:2007 | 09 | 2007 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,605 | $1,000 | Not Implemented |
MA0624 # 10 Y:2007 | 10 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,007 | $12,000 | Implemented |
MA0624 # 11 Y:2007 | 11 | 2007 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,570 | $15,700 | Not Implemented |
MA0624 # 12 Y:2007 | 12 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,045 | $5,670 | Implemented |
NC0165 # 01 Y:1999 | 01 | 1999 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $28,720 | $10,000 | Implemented |
NC0165 # 02 Y:1999 | 02 | 1999 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,539 | $1,500 | Implemented |
NC0165 # 03 Y:1999 | 03 | 1999 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $151,290 | $29,000 | Implemented |
NC0165 # 04 Y:1999 | 04 | 1999 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $231,300 | $1,600,000 | Not Implemented |
NC0165 # 05 Y:1999 | 05 | 1999 | INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT | $824,740 | $836,000 | Implemented |
UD0576 # 01 Y:1999 | 01 | 1999 | AUTOMATE FINISHING PROCESS | $270,000 | $150,000 | Not Implemented |
UD0576 # 02 Y:1999 | 02 | 1999 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $269,087 | $365,000 | Not Implemented |
UD0576 # 03 Y:1999 | 03 | 1999 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,377 | $4,700 | Implemented |