Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
334
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0016 # 01 Y:2001 | 01 | 2001 | REPLACE BOILER | $420,482 | $9,456 | Implemented |
TA0016 # 02 Y:2001 | 02 | 2001 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $15,055 | $600 | Implemented |
TA0016 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $13,585 | $2,910 | Implemented |
TA0016 # 04 Y:2001 | 04 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,090 | $1,200 | Implemented |
TA0016 # 05 Y:2001 | 05 | 2001 | COVER OPEN TANKS | $2,000 | $3,900 | Not Implemented |
TA0016 # 06 Y:2001 | 06 | 2001 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,920 | $54 | Implemented |
TA0016 # 07 Y:2001 | 07 | 2001 | USE PHOTOCELL CONTROLS | $1,696 | $225 | Implemented |
TA0016 # 08 Y:2001 | 08 | 2001 | USE SYNTHETIC LUBRICANT | $1,600 | $0 | Not Implemented |
TA0016 # 09 Y:2001 | 09 | 2001 | INSTALL OCCUPANCY SENSORS | $1,032 | $320 | Implemented |
TA0016 # 10 Y:2001 | 10 | 2001 | DISCONNECT BALLASTS | $510 | $982 | Not Implemented |
TA0016 # 11 Y:2001 | 11 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $254 | $542 | Implemented |
TP0018 # 04 Y:2000 | 04 | 2000 | INSTALL OCCUPANCY SENSORS | $279 | $847 | Not Implemented |
TP0018 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $843 | $700 | Not Implemented |
TP0018 # 02 Y:2000 | 02 | 2000 | INSTALL DEDICATED MIXING EQUIP TO OPTIMIZE REUSE OF USED RINSEATE & TO PRECLUDE THE NEED FOR INTER-RUN CLEANING | $3,716 | $2,056 | Not Implemented |
TP0018 # 01 Y:2000 | 01 | 2000 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $52,800 | $48,300 | Not Implemented |
TP0008 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,456 | $35,097 | Not Implemented |
TP0008 # 06 Y:1999 | 06 | 1999 | USE SYNTHETIC LUBRICANT | $1,248 | $0 | Not Implemented |
TP0008 # 01 Y:1999 | 01 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $24,189 | $1,848 | Implemented |
TP0008 # 02 Y:1999 | 02 | 1999 | OPTIMIZE PLANT POWER FACTOR | $33,041 | $51,500 | Not Implemented |
TP0008 # 03 Y:1999 | 03 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $36,820 | $1,728 | Not Implemented |
TP0008 # 04 Y:1999 | 04 | 1999 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $7,545 | $2,000 | Not Implemented |
AM0321 # 01 Y:1998 | 01 | 1998 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $21,130 | $49,220 | Not Implemented |
AM0321 # 02 Y:1998 | 02 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,825 | $600 | Implemented |
AM0321 # 03 Y:1998 | 03 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,630 | $40 | Not Implemented |
AM0321 # 04 Y:1998 | 04 | 1998 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,470 | $0 | Not Implemented |