Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,523
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BS0036 # 01 Y:2014 | 01 | 2014 | USE OPTIMUM THICKNESS INSULATION | $17,744 | $26,100 | Not Implemented |
BS0036 # 02 Y:2014 | 02 | 2014 | INSTALL REPLACEMENT DOORS | $4,556 | $17,436 | Not Implemented |
BS0036 # 03 Y:2014 | 03 | 2014 | INSTALL EQUIPMENT TO UTILIZE WASTE FUEL | $16,582 | $31,134 | Not Implemented |
BS0036 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,961 | $10,130 | Not Implemented |
BS0036 # 05 Y:2014 | 05 | 2014 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,250 | $11,371 | Not Implemented |
BS0036 # 06 Y:2014 | 06 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,963 | $937 | Implemented |
BS0036 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $16,898 | $2,032 | Implemented |
OK0889 # 01 Y:2014 | 01 | 2014 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $15,746 | $14,500 | Not Implemented |
OK0889 # 02 Y:2014 | 02 | 2014 | SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS | $4,415 | $7,547 | Not Implemented |
OK0889 # 03 Y:2014 | 03 | 2014 | INSTALL TIMERS AND/OR THERMOSTATS | $10,189 | $4,650 | Implemented |
OK0889 # 04 Y:2014 | 04 | 2014 | REPLACE HIGH RESISTANCE DUCTS, PIPES, AND FITTINGS | $4,444 | $6,994 | Not Implemented |
OK0889 # 05 Y:2014 | 05 | 2014 | INSTALL OCCUPANCY SENSORS | $1,519 | $5,372 | Not Implemented |
OK0889 # 06 Y:2014 | 06 | 2014 | INSTALL OCCUPANCY SENSORS | $200 | $696 | Not Implemented |
OK0889 # 07 Y:2014 | 07 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,946 | $320 | Not Implemented |
OK0889 # 08 Y:2014 | 08 | 2014 | USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING | $815 | $250 | Not Implemented |
OK0889 # 09 Y:2014 | 09 | 2014 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,124 | $239 | Implemented |
OK0889 # 10 Y:2014 | 10 | 2014 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $2,920 | $10,599 | Implemented |
OK0889 # 11 Y:2014 | 11 | 2014 | OPTIMIZE PLANT POWER FACTOR | $4,264 | $2,925 | Not Implemented |
MI0266 # 01 Y:2014 | 01 | 2014 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $12,844 | $14,320 | Not Implemented |
MI0266 # 02 Y:2014 | 02 | 2014 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $8,400 | $800 | Implemented |
MI0266 # 03 Y:2014 | 03 | 2014 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $7,871 | $640 | Implemented |
MI0266 # 04 Y:2014 | 04 | 2014 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,868 | $3,500 | Not Implemented |
MI0266 # 05 Y:2014 | 05 | 2014 | INSTALL SKYLIGHTS | $5,746 | $630 | Implemented |
MI0266 # 06 Y:2014 | 06 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,486 | $1,310 | Implemented |
MI0266 # 07 Y:2014 | 07 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,344 | $9,120 | Implemented |