Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,523
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0890 # 02 Y:2013 | 02 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,847 | $0 | Not Implemented |
UD0890 # 03 Y:2013 | 03 | 2013 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $37,340 | $0 | Implemented |
UD0890 # 04 Y:2013 | 04 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $136,711 | $0 | Implemented |
UD0890 # 05 Y:2013 | 05 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,587 | $19,427 | Not Implemented |
UD0890 # 06 Y:2013 | 06 | 2013 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,216 | $0 | Implemented |
UD0890 # 07 Y:2013 | 07 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $37,438 | $6,000 | Implemented |
UD0890 # 08 Y:2013 | 08 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,203 | $0 | Implemented |
UD0890 # 09 Y:2013 | 09 | 2013 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $176,886 | $101,000 | Not Implemented |
UD0890 # 10 Y:2013 | 10 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $746,973 | $100,000 | Not Implemented |
UD0890 # 11 Y:2013 | 11 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $565,879 | $1,157,500 | Not Implemented |
UD0890 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $19,159 | $0 | Not Implemented |
BS0022 # 01 Y:2013 | 01 | 2013 | CHANGE PRODUCT DESIGN TO REDUCE ENERGY REQUIREMENTS | $3,444 | $500 | Implemented |
BS0022 # 02 Y:2013 | 02 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $2,989 | $218 | Implemented |
BS0022 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,022 | $26,934 | Not Implemented |
BS0022 # 04 Y:2013 | 04 | 2013 | COVER OPEN TANKS | $418 | $310 | Not Implemented |
BS0022 # 05 Y:2013 | 05 | 2013 | REPAIR AND ELIMINATE STEAM LEAKS | $1,748 | $697 | Implemented |
BS0022 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $871 | $15 | Implemented |
WM0030 # 01 Y:2013 | 01 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,439 | $1,853 | Not Implemented |
WM0030 # 02 Y:2013 | 02 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $17,111 | $9,180 | Not Implemented |
WM0030 # 03 Y:2013 | 03 | 2013 | USE PHOTOCELL CONTROLS | $2,234 | $4,550 | Not Implemented |
WM0030 # 04 Y:2013 | 04 | 2013 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,570 | $500 | Not Implemented |
WM0030 # 05 Y:2013 | 05 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,064 | $0 | Not Implemented |
WM0030 # 06 Y:2013 | 06 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $34,398 | $69,000 | Implemented |
WM0030 # 07 Y:2013 | 07 | 2013 | MODIFY STARTUP/SHUTDOWN TIMES | $3,034 | $0 | Not Implemented |
WM0030 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $473 | $546 | Not Implemented |