Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,523
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0813 # 09 Y:2010 | 09 | 2010 | COVER OPEN TANKS | $1,174 | $1,468 | Not Implemented |
UD0813 # 10 Y:2010 | 10 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,098 | $0 | Not Implemented |
UD0813 # 11 Y:2010 | 11 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,559 | $0 | Not Implemented |
UD0813 # 12 Y:2010 | 12 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $16,732 | $15,000 | Not Implemented |
UD0813 # 13 Y:2010 | 13 | 2010 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,280 | $15,000 | Not Implemented |
UD0813 # 01 Y:2010 | 01 | 2010 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $41,029 | $28,680 | Not Implemented |
MA0656 # 01 Y:2010 | 01 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $33,238 | $900 | Implemented |
MA0656 # 02 Y:2010 | 02 | 2010 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $32,273 | $19,075 | Not Implemented |
MA0656 # 03 Y:2010 | 03 | 2010 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,578 | $2,400 | Not Implemented |
MA0656 # 04 Y:2010 | 04 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,891 | $15,755 | Not Implemented |
MA0656 # 05 Y:2010 | 05 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,718 | $3,915 | Implemented |
MA0656 # 06 Y:2010 | 06 | 2010 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $36,936 | $68,200 | Implemented |
MA0656 # 07 Y:2010 | 07 | 2010 | BURN A LESS EXPENSIVE GRADE OF FUEL | $54,013 | $100,000 | Implemented |
MA0656 # 08 Y:2010 | 08 | 2010 | INSTALL OCCUPANCY SENSORS | $1,714 | $3,865 | Implemented |
SU0289 # 01 Y:2010 | 01 | 2010 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $13,013 | $0 | Implemented |
SU0289 # 02 Y:2010 | 02 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,573 | $0 | Implemented |
SU0289 # 03 Y:2010 | 03 | 2010 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,552 | $0 | Implemented |
SU0289 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,383 | $578 | Implemented |
SU0289 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,787 | $964 | Not Implemented |
SU0289 # 06 Y:2010 | 06 | 2010 | INSTALL OCCUPANCY SENSORS | $1,653 | $1,236 | Implemented |
SU0289 # 07 Y:2010 | 07 | 2010 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $528 | $714 | Implemented |
SU0289 # 08 Y:2010 | 08 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,267 | $8,373 | Not Implemented |
UA0041 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $55,100 | $119,700 | Implemented |
UA0041 # 02 Y:2010 | 02 | 2010 | INSTALL OCCUPANCY SENSORS | $2,630 | $380 | Not Implemented |
UA0041 # 03 Y:2010 | 03 | 2010 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $5,320 | $2,520 | Implemented |