Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,490
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0659 # 06 Y:1999 | 06 | 1999 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $45,013 | $120,000 | n/a |
SD0239 # 01 Y:2000 | 01 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,960 | $300 | Not Implemented |
SD0239 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,716 | $0 | Implemented |
SD0239 # 03 Y:2000 | 03 | 2000 | CONVERT TO ELECTROSTATIC POWDER COATING | $7,470 | $56,000 | Not Implemented |
SD0239 # 04 Y:2000 | 04 | 2000 | $45,475 | $66,000 | Not Implemented | |
SD0239 # 05 Y:2000 | 05 | 2000 | $40,500 | $7,500 | Implemented | |
WV0185 # 01 Y:2000 | 01 | 2000 | INSTALL SKYLIGHTS | $734 | $3,000 | Not Implemented |
WV0185 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $683 | $240 | Implemented |
WV0185 # 03 Y:2000 | 03 | 2000 | USE RADIANT HEATER FOR SPOT HEATING | $5,858 | $6,900 | Implemented |
WV0185 # 04 Y:2000 | 04 | 2000 | USE SYNTHETIC LUBRICANT | $397 | $417 | Implemented |
WV0185 # 05 Y:2000 | 05 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $4,368 | $4,872 | Not Implemented |
WV0185 # 06 Y:2000 | 06 | 2000 | INSTALL OCCUPANCY SENSORS | $3,368 | $400 | Not Implemented |
WV0185 # 07 Y:2000 | 07 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $13,587 | $200 | Not Implemented |
WV0185 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $12,960 | $800 | Implemented |
WV0185 # 09 Y:2000 | 09 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $5,851 | $1,850 | Implemented |
WV0185 # 10 Y:2000 | 10 | 2000 | $8,000 | $500 | Not Implemented | |
OK0591 # 01 Y:2000 | 01 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $315 | $1,900 | Implemented |
OK0591 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,477 | $4,942 | Implemented |
OK0591 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $875 | $136 | Not Implemented |
OK0591 # 04 Y:2000 | 04 | 2000 | BURN A LESS EXPENSIVE GRADE OF FUEL | $9,042 | $230,000 | Not Implemented |
OK0591 # 05 Y:2000 | 05 | 2000 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $181,048 | $59,400 | Not Implemented |
OK0591 # 06 Y:2000 | 06 | 2000 | $21,407 | $30,000 | Not Implemented | |
GT0678 # 01 Y:1999 | 01 | 1999 | METER WASTE WATER | $4,925 | $900 | Implemented |
GT0678 # 02 Y:1999 | 02 | 1999 | REDUCE EXCESSIVE BOILER BLOWDOWN | $920 | $900 | Not Implemented |
GT0678 # 03 Y:1999 | 03 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,880 | $3,500 | Not Implemented |