Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
281
matching recommendationsSIC | 37 | Transportation Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0010 # 06 Y:2008 | 06 | 2008 | UPGRADE CONTROLS ON COMPRESSORS | $2,625 | $5,250 | Implemented |
TT0010 # 07 Y:2008 | 07 | 2008 | OPTIMIZE PLANT POWER FACTOR | $8,302 | $48,000 | Not Implemented |
UD0769 # 01 Y:2007 | 01 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $126,798 | $0 | Implemented |
UD0769 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $119,000 | $0 | Implemented |
UD0769 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $63,509 | $110,000 | Implemented |
UD0769 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,170 | $110,000 | Implemented |
UD0769 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $44,667 | $28,125 | Implemented |
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
UD0769 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $25,268 | $0 | Implemented |
UD0769 # 08 Y:2007 | 08 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,200 | $400 | Implemented |
UD0769 # 09 Y:2007 | 09 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,400 | $600 | Not Implemented |
UD0769 # 10 Y:2007 | 10 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,000 | $25,000 | Not Implemented |
UD0769 # 11 Y:2007 | 11 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,569 | $3,275 | Implemented |
UD0769 # 12 Y:2007 | 12 | 2007 | REDUCE VENTILATION AIR | $17,703 | $26,910 | Not Implemented |
UD0769 # 13 Y:2007 | 13 | 2007 | UPGRADE CONTROLS ON COMPRESSORS | $3,980 | $0 | Implemented |
UD0769 # 14 Y:2007 | 14 | 2007 | REDUCE VENTILATION AIR | $2,208 | $590 | Implemented |
UD0769 # 15 Y:2007 | 15 | 2007 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $1,800 | $500 | Implemented |
UD0769 # 16 Y:2007 | 16 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,447 | $520 | Implemented |
UD0769 # 17 Y:2007 | 17 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,242 | $0 | Implemented |
UL0249 # 01 Y:2000 | 01 | 2000 | INSTALL SKYLIGHTS | $4,840 | $5,700 | Implemented |
UL0249 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,210 | $0 | Implemented |
UL0249 # 03 Y:2000 | 03 | 2000 | MINIMIZE WATER USAGE | $3,539 | $909 | Not Implemented |
UL0249 # 04 Y:2000 | 04 | 2000 | SWITCH TO A SOLVENT THAT CAN BE CLEANED AND RE-USED | $1,537 | $700 | Not Implemented |
UL0249 # 05 Y:2000 | 05 | 2000 | COMBINE UTILITY METERS | $3,900 | $5,000 | Implemented |
TN0690 # 01 Y:2000 | 01 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $272,160 | $169,485 | Not Implemented |