Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

23

matching recommendations
Reset
SIC 37 Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0126 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $284 $70 Implemented
NV0126 # 02 Y:1999 02 1999 UPGRADE CONTROLS ON COMPRESSORS $1,034 $500 Not Implemented
NV0126 # 03 Y:1999 03 1999 USE RADIANT HEATER FOR SPOT HEATING $6,540 $7,980 Not Implemented
NV0126 # 04 Y:1999 04 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $821 $1,300 Implemented
NV0126 # 05 Y:1999 05 1999 INSTALL TIMERS AND/OR THERMOSTATS $4,515 $1,400 Implemented
NV0075 # 06 Y:1996 06 1996 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE $400 $0 Not Implemented
NV0075 # 05 Y:1996 05 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $845 $1,625 Not Implemented
NV0075 # 01 Y:1996 01 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,155 $600 Implemented
NV0075 # 02 Y:1996 02 1996 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,773 $425 Not Implemented
NV0075 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $617 $227 Not Implemented
NV0075 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $307 $300 Not Implemented
NV0032 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $2,946 $2,937 Not Implemented
NV0032 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $3,702 $1,741 Not Implemented
NV0032 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $289 $400 Not Implemented
NV0032 # 02 Y:1995 02 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $291 $0 Implemented
NV0032 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $640 $3,211 Implemented
NV0030 # 07 Y:1995 07 1995 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $6,740 $11,490 Not Implemented
NV0030 # 06 Y:1995 06 1995 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $564 $114 Not Implemented
NV0030 # 05 Y:1995 05 1995 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $963 $0 Implemented
NV0030 # 04 Y:1995 04 1995 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $833 $0 Not Implemented
NV0030 # 03 Y:1995 03 1995 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,433 $6,500 Not Implemented
NV0030 # 02 Y:1995 02 1995 INSTALL SPECTRAL REFLECTORS / DELAMP $2,584 $100 Not Implemented
NV0030 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,268 $3,296 Not Implemented