Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,381
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0119 # 06 Y:1995 | 06 | 1995 | USE OPTIMUM THICKNESS INSULATION | $303 | $1,020 | Implemented |
IA0119 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $948 | $169 | Implemented |
IA0119 # 09 Y:1995 | 09 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $909 | $1,570 | Implemented |
MS0030 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,709 | $3,855 | Implemented |
MS0030 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $579 | $1,200 | Implemented |
MS0030 # 07 Y:1995 | 07 | 1995 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $125 | $20 | Implemented |
ME0164 # 01 Y:1995 | 01 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,205 | $0 | Implemented |
ME0164 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $901 | $600 | Implemented |
ME0164 # 05 Y:1995 | 05 | 1995 | KEEP EQUIPMENT CLEAN | $728 | $300 | Implemented |
ME0164 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $294 | $515 | Implemented |
ME0164 # 08 Y:1995 | 08 | 1995 | USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL | $7,418 | $4,000 | Implemented |
ME0164 # 09 Y:1995 | 09 | 1995 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $5,904 | $10,025 | Implemented |
ME0164 # 10 Y:1995 | 10 | 1995 | MINIMIZE WATER USAGE | $1,022 | $75 | Implemented |
AM0246 # 02 Y:1995 | 02 | 1995 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,618 | $0 | Implemented |
AM0246 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,550 | $500 | Implemented |
AM0246 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $950 | $0 | Implemented |
NV0030 # 05 Y:1995 | 05 | 1995 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $963 | $0 | Implemented |
ND0209 # 02 Y:1995 | 02 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,079 | $1,200 | Implemented |
ND0209 # 03 Y:1995 | 03 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,016 | $490 | Implemented |
ND0209 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,749 | $7,975 | Implemented |
IA0111 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,777 | $9,655 | Implemented |
IA0111 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,029 | $500 | Implemented |
IA0111 # 08 Y:1995 | 08 | 1995 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $1,672 | $8,000 | Implemented |
UD0458 # 01 Y:1995 | 01 | 1995 | OPTIMIZE PLANT POWER FACTOR | $11,292 | $25,000 | Implemented |
UD0458 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $23,747 | $5,000 | Implemented |