Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,374

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0602 # 04 Y:1997 04 1997 USE RADIANT HEATER FOR SPOT HEATING $96,084 $35,020 Implemented
TN0602 # 05 Y:1997 05 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $16,339 $3,000 Implemented
TN0602 # 06 Y:1997 06 1997 ADD AREA LIGHTING SWITCHES $11,208 $13,340 Implemented
TN0602 # 07 Y:1997 07 1997 INSTALL TIMERS AND/OR THERMOSTATS $10,349 $2,016 Implemented
TN0602 # 08 Y:1997 08 1997 REUSE / RECYCLE/ SELL PAPER PRODUCTS $3,540 $8,288 Implemented
TN0597 # 01 Y:1997 01 1997 RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION $420,000 $0 Implemented
TN0597 # 02 Y:1997 02 1997 ELIMINATE THIRD SHIFT $35,200 $116,600 Not Implemented
TN0597 # 03 Y:1997 03 1997 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $10,210 $0 Implemented
TN0597 # 04 Y:1997 04 1997 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS $4,865 $0 Implemented
TN0597 # 05 Y:1997 05 1997 USE A RAG RECYCLE SERVICE $3,800 $0 Not Implemented
TN0597 # 06 Y:1997 06 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,710 $2,000 Implemented
TN0597 # 07 Y:1997 07 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,180 $800 Implemented
TN0597 # 08 Y:1997 08 1997 INSTALL TIMERS AND/OR THERMOSTATS $1,830 $0 Implemented
TN0597 # 09 Y:1997 09 1997 MODIFY MATERIAL APPLICATION METHODS $1,560 $4,400 Implemented
TN0597 # 10 Y:1997 10 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $640 $460 Implemented
UM0075 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,113 $1,780 Implemented
UM0075 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $24,516 $61,663 Not Implemented
UM0075 # 03 Y:1996 03 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,084 $810 Not Implemented
UM0075 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,091 $450 Implemented
UM0075 # 05 Y:1996 05 1996 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $1,700 $800 Implemented
UM0075 # 06 Y:1996 06 1996 USE OTHER WASTE CONCENTRATION METHODS $3,084 $0 Not Implemented
CO0377 # 01 Y:1996 01 1996 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $517,560 $5,000 Not Implemented
CO0377 # 02 Y:1996 02 1996 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $7,610 $50,000 Not Implemented
CO0377 # 03 Y:1996 03 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $2,810 $6,710 Not Implemented
CO0377 # 04 Y:1996 04 1996 DISTILL CONTAMINATED SOLVENTS FOR REUSE $1,865 $3,550 Not Implemented