Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,441
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0115 # 08 Y:1984 | 08 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $519 | $790 | Implemented |
OK0115 # 09 Y:1984 | 09 | 1984 | REDUCE LOAD ON ELECTRICAL CONDUCTOR TO REDUCE HEATING LOSSES | $740 | $1,125 | Not Implemented |
OK0115 # 10 Y:1984 | 10 | 1984 | INSULATE BARE EQUIPMENT | $900 | $46 | Implemented |
OK0115 # 11 Y:1984 | 11 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $2,676 | $278 | Implemented |
OK0115 # 12 Y:1984 | 12 | 1984 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $356 | $371 | Implemented |
OK0115 # 13 Y:1984 | 13 | 1984 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,802 | $200 | Implemented |
KU0106 # 01 Y:1983 | 01 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $487 | $150 | Not Implemented |
KU0106 # 02 Y:1983 | 02 | 1983 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $636 | $375 | Not Implemented |
KU0106 # 03 Y:1983 | 03 | 1983 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,124 | $0 | Not Implemented |
KU0106 # 04 Y:1983 | 04 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,926 | $1,260 | Not Implemented |
KU0106 # 05 Y:1983 | 05 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $2,414 | $4,100 | Not Implemented |
KU0106 # 06 Y:1983 | 06 | 1983 | USE OPTIMUM THICKNESS INSULATION | $498 | $100 | Implemented |
KU0106 # 07 Y:1983 | 07 | 1983 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,846 | $1,000 | Not Implemented |
KU0106 # 08 Y:1983 | 08 | 1983 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $342 | $80 | Implemented |
KU0106 # 09 Y:1983 | 09 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,291 | $7,951 | Not Implemented |
KU0106 # 10 Y:1983 | 10 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $12,782 | $10 | Not Implemented |
KU0106 # 11 Y:1983 | 11 | 1983 | REDUCE VENTILATION AIR | $1,554 | $0 | Not Implemented |
TN0150 # 01 Y:1982 | 01 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $662 | $492 | Not Implemented |
TN0150 # 02 Y:1982 | 02 | 1982 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $3,328 | $0 | Not Implemented |
TN0150 # 03 Y:1982 | 03 | 1982 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $2,926 | $1,563 | Not Implemented |
TN0130 # 01 Y:1982 | 01 | 1982 | TURN OFF EQUIPMENT WHEN NOT IN USE | $15,419 | $3,500 | Not Implemented |
TN0130 # 02 Y:1982 | 02 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $7,571 | $5,400 | Not Implemented |
TN0130 # 03 Y:1982 | 03 | 1982 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,269 | $1,000 | Not Implemented |
TN0130 # 04 Y:1982 | 04 | 1982 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $1,775 | $3,320 | Not Implemented |
UD0023 # 01 Y:1982 | 01 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $7,104 | $6,705 | Implemented |