Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
232
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IC0146 # 10 Y:2008 | 10 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $487 | $424 | Implemented |
IC0146 # 11 Y:2008 | 11 | 2008 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $679 | $0 | Implemented |
IC0146 # 12 Y:2008 | 12 | 2008 | CONVERT COMBUSTION EQUIPMENT TO BURN OIL | $27,915 | $32,868 | Not Implemented |
IC0146 # 13 Y:2008 | 13 | 2008 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $12,315 | $0 | Not Implemented |
IC0131 # 01 Y:2007 | 01 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,220 | $65,800 | Implemented |
IC0131 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,150 | $105,762 | Implemented |
IC0131 # 03 Y:2007 | 03 | 2007 | INSTALL OCCUPANCY SENSORS | $1,159 | $3,681 | Implemented |
IC0131 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,771 | $6,442 | Not Implemented |
IC0131 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $516 | $677 | Implemented |
IC0131 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $149 | $930 | Implemented |
IC0131 # 07 Y:2007 | 07 | 2007 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $87 | $0 | Not Implemented |
IC0131 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,867 | $8,430 | Implemented |
IC0131 # 09 Y:2007 | 09 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,474 | $3,192 | Implemented |
IC0131 # 10 Y:2007 | 10 | 2007 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $650 | $0 | Not Implemented |
IC0131 # 11 Y:2007 | 11 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $864 | $1 | Not Implemented |
IC0131 # 12 Y:2007 | 12 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $18,231 | $1 | Not Implemented |
IC0131 # 13 Y:2007 | 13 | 2007 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $1,393 | $1 | Not Implemented |
IC0131 # 14 Y:2007 | 14 | 2007 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $956 | $7,500 | Not Implemented |
IC0131 # 15 Y:2007 | 15 | 2007 | MINIMIZE WATER USAGE | $7,267 | $15,000 | Implemented |
IC0131 # 16 Y:2007 | 16 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $32 | $1 | Implemented |
IC0131 # 17 Y:2007 | 17 | 2007 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $5,723 | $15,000 | Implemented |
IC0131 # 18 Y:2007 | 18 | 2007 | MODIFY CURRENT INCENTIVE PROGRAM | $19,189 | $38,378 | Implemented |
BD0309 # 01 Y:2006 | 01 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $23,664 | $27,472 | Not Implemented |
BD0309 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,400 | $1,800 | Implemented |
BD0309 # 03 Y:2006 | 03 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,190 | $0 | Implemented |