IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,507

matching recommendations
Reset
SIC 371 Motor Vehicles And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TT0060 # 10 Y:2011 10 2011 INSTALL TIMERS AND/OR THERMOSTATS $3,700 $1,600 Not Implemented
TT0060 # 11 Y:2011 11 2011 INSTALL TIMERS AND/OR THERMOSTATS $500 $600 Not Implemented
TT0060 # 12 Y:2011 12 2011 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,280 $0 Not Implemented
UA3014 # 01 Y:2011 01 2011 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $78,640 $8,320 Implemented
UA3014 # 02 Y:2011 02 2011 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $71,901 $30,750 Not Implemented
UA3014 # 03 Y:2011 03 2011 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $72,048 $98,000 Not Implemented
UA3014 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,700 $60,860 Not Implemented
UA3014 # 05 Y:2011 05 2011 INSTALL OCCUPANCY SENSORS $20,767 $13,730 Implemented
UA3014 # 06 Y:2011 06 2011 DISCONNECT BALLASTS $5,801 $405 Implemented
UA3014 # 07 Y:2011 07 2011 OPTIMIZE PLANT POWER FACTOR $29,663 $26,400 Not Implemented
UA3014 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $92,285 $51,748 Not Implemented
UA3014 # 09 Y:2011 09 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $269,372 $630,225 Not Implemented
BD0384 # 01 Y:2011 01 2011 USE RADIANT HEATER FOR SPOT HEATING $50,720 $73,600 Implemented
BD0384 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $32,663 $45,984 Implemented
BD0384 # 03 Y:2011 03 2011 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES $13,232 $3,000 Not Implemented
BD0384 # 04 Y:2011 04 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,079 $1,400 Not Implemented
BD0384 # 05 Y:2011 05 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,049 $5,100 Implemented
BD0384 # 06 Y:2011 06 2011 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,941 $2,000 Implemented
BD0384 # 07 Y:2011 07 2011 INSTALL OCCUPANCY SENSORS $1,067 $1,067 Implemented
BD0384 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $614 $525 Implemented
BD0384 # 09 Y:2011 09 2011 USE EVAPORATION TO CONCENTRATE MATERIAL $949 $705 Not Implemented
BD0384 # 10 Y:2011 10 2011 MODIFY STARTUP/SHUTDOWN TIMES $543 $20 Not Implemented
UA3005 # 01 Y:2010 01 2010 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $30,246 $34,285 Not Implemented
UA3005 # 02 Y:2010 02 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $27,085 $42,861 Implemented
UA3005 # 03 Y:2010 03 2010 INSTALL OCCUPANCY SENSORS $2,974 $730 Not Implemented