Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
114
matching recommendationsSIC | 371 | Motor Vehicles And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0014 # 04 Y:2007 | 04 | 2007 | INCREASE ELECTRICAL CONDUCTOR SIZE TO REDUCE DISTRIBUTION LOSSES | $44,581 | $51,000 | Implemented |
TT0014 # 01 Y:2007 | 01 | 2007 | INSTALL OCCUPANCY SENSORS | $541 | $360 | Not Implemented |
TT0014 # 02 Y:2007 | 02 | 2007 | APPLY FOR INVESTMENT INCENTIVES | $21,551 | $110 | Implemented |
TT0014 # 05 Y:2007 | 05 | 2007 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $159,283 | $2,912 | Implemented |
TT0014 # 03 Y:2007 | 03 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $13,359 | $1,200 | Not Implemented |
IC0134 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $2,672 | $3,121 | Implemented |
UD0769 # 10 Y:2007 | 10 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,000 | $25,000 | Not Implemented |
UD0769 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $25,268 | $0 | Implemented |
UD0769 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $44,667 | $28,125 | Implemented |
UD0769 # 08 Y:2007 | 08 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,200 | $400 | Implemented |
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
IC0134 # 10 Y:2007 | 10 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $382 | $1,026 | Implemented |
IC0134 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,787 | $0 | Implemented |
UD0769 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $63,509 | $110,000 | Implemented |
UD0769 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $119,000 | $0 | Implemented |
UD0769 # 01 Y:2007 | 01 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $126,798 | $0 | Implemented |
UD0769 # 09 Y:2007 | 09 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,400 | $600 | Not Implemented |
UD0769 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,170 | $110,000 | Implemented |
IC0134 # 01 Y:2007 | 01 | 2007 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $50,624 | $28,500 | Not Implemented |
IC0134 # 02 Y:2007 | 02 | 2007 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $24,453 | $77,470 | Not Implemented |
IC0134 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,207 | $3,120 | Not Implemented |
IC0134 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,810 | $4,071 | Not Implemented |
IC0134 # 03 Y:2007 | 03 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $14,325 | $0 | Not Implemented |
IC0134 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,173 | $9,173 | Implemented |
IC0134 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,889 | $167,364 | Implemented |