Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
512
matching recommendationsSIC | 3713 | Truck And Bus Bodies |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0384 # 09 Y:2011 | 09 | 2011 | USE EVAPORATION TO CONCENTRATE MATERIAL | $949 | $705 | Not Implemented |
BD0384 # 10 Y:2011 | 10 | 2011 | MODIFY STARTUP/SHUTDOWN TIMES | $543 | $20 | Not Implemented |
UA3005 # 01 Y:2010 | 01 | 2010 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $30,246 | $34,285 | Not Implemented |
UA3005 # 02 Y:2010 | 02 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,085 | $42,861 | Implemented |
UA3005 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,974 | $730 | Not Implemented |
UA3005 # 04 Y:2010 | 04 | 2010 | UPGRADE CONTROLS ON COMPRESSORS | $9,502 | $20,000 | Implemented |
UA3005 # 05 Y:2010 | 05 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,061 | $5,448 | Not Implemented |
UA3005 # 06 Y:2010 | 06 | 2010 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,840 | $400 | Not Implemented |
UA3005 # 07 Y:2010 | 07 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,333 | $1,000 | Not Implemented |
UA3005 # 08 Y:2010 | 08 | 2010 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $122,417 | $2,400 | Implemented |
UA3005 # 09 Y:2010 | 09 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,056 | $2,750 | Not Implemented |
UA3005 # 10 Y:2010 | 10 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $2,972 | $510 | Not Implemented |
UM0368 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $44,687 | $124,913 | Not Implemented |
UM0368 # 02 Y:2010 | 02 | 2010 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,110 | $6,000 | Not Implemented |
UM0368 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,430 | $2,852 | Not Implemented |
UM0368 # 04 Y:2010 | 04 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $34,139 | $333,550 | Not Implemented |
UM0368 # 05 Y:2010 | 05 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,327 | $574 | Not Implemented |
UM0368 # 06 Y:2010 | 06 | 2010 | INSTALL STORM WINDOWS AND DOORS | $1,579 | $8,070 | Not Implemented |
UM0368 # 07 Y:2010 | 07 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,164 | $1,000 | Not Implemented |
IA0449 # 01 Y:2010 | 01 | 2010 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $13,384 | $500 | Not Implemented |
IA0449 # 02 Y:2010 | 02 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,171 | $500 | Implemented |
IA0449 # 03 Y:2010 | 03 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,181 | $650 | Implemented |
IA0449 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,025 | $28,980 | Implemented |
IA0449 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $229 | $1,199 | Implemented |
IA0449 # 06 Y:2010 | 06 | 2010 | INSULATE BARE EQUIPMENT | $5,734 | $1,910 | Implemented |