Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
63
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0543 # 07 Y:2015 | 07 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $9,398 | $21,800 | Not Implemented |
NC0543 # 11 Y:2015 | 11 | 2015 | DEVELOP A REPAIR/REPLACE POLICY | $2,491 | $4,256 | Not Implemented |
NC0543 # 12 Y:2015 | 12 | 2015 | USE EVAPORATION TO CONCENTRATE MATERIAL | $4,794 | $19,000 | Not Implemented |
NC0543 # 10 Y:2015 | 10 | 2015 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,618 | $20,000 | Not Implemented |
NC0543 # 09 Y:2015 | 09 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $311 | $80 | Implemented |
NC0543 # 08 Y:2015 | 08 | 2015 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $192 | $500 | Implemented |
NC0543 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $64,078 | $68,997 | Implemented |
TT0017 # 05 Y:2008 | 05 | 2008 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,947 | $17,385 | Not Implemented |
TT0017 # 04 Y:2008 | 04 | 2008 | INSTALL SKYLIGHTS | $12,995 | $22,450 | Not Implemented |
TT0017 # 03 Y:2008 | 03 | 2008 | OPTIMIZE PLANT POWER FACTOR | $1,370 | $5,170 | Not Implemented |
TT0017 # 02 Y:2008 | 02 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $302 | $324 | Not Implemented |
TT0017 # 01 Y:2008 | 01 | 2008 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $13,583 | $1,715 | Not Implemented |
TN0667 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $15,168 | $29,100 | Not Implemented |
TN0667 # 01 Y:1999 | 01 | 1999 | RECOVER AND REUSE WASTE MATERIAL | $222,220 | $77,760 | Not Implemented |
TN0667 # 02 Y:1999 | 02 | 1999 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $52,782 | $80,100 | Implemented |
TN0667 # 03 Y:1999 | 03 | 1999 | METER WASTE WATER | $26,280 | $2,980 | Implemented |
TN0667 # 04 Y:1999 | 04 | 1999 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $22,500 | $25,000 | Not Implemented |
TN0667 # 05 Y:1999 | 05 | 1999 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $20,700 | $21,780 | Not Implemented |
TN0645 # 02 Y:1998 | 02 | 1998 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $277,345 | $644,800 | Not Implemented |
TN0645 # 01 Y:1998 | 01 | 1998 | ALLOW DRAINAGE BEFORE WITHDRAWING OBJECT | $408,630 | $24,685 | Implemented |
TN0645 # 03 Y:1998 | 03 | 1998 | REDUCE SOLUTION DRAG-OUT TO PREVENT SOLUTION LOSS | $237,600 | $153,485 | Not Implemented |
TN0645 # 11 Y:1998 | 11 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,880 | $5,000 | Implemented |
TN0645 # 10 Y:1998 | 10 | 1998 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $9,390 | $8,000 | Implemented |
TN0645 # 09 Y:1998 | 09 | 1998 | INSTALL SET-BACK TIMERS | $15,755 | $1,555 | Not Implemented |
TN0645 # 04 Y:1998 | 04 | 1998 | SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE | $221,455 | $70,000 | Not Implemented |