Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
98
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0014 # 04 Y:2007 | 04 | 2007 | INCREASE ELECTRICAL CONDUCTOR SIZE TO REDUCE DISTRIBUTION LOSSES | $44,581 | $51,000 | Implemented |
TT0014 # 02 Y:2007 | 02 | 2007 | APPLY FOR INVESTMENT INCENTIVES | $21,551 | $110 | Implemented |
TT0014 # 03 Y:2007 | 03 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $13,359 | $1,200 | Not Implemented |
TT0014 # 05 Y:2007 | 05 | 2007 | ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM | $159,283 | $2,912 | Implemented |
TT0014 # 01 Y:2007 | 01 | 2007 | INSTALL OCCUPANCY SENSORS | $541 | $360 | Not Implemented |
UD0769 # 09 Y:2007 | 09 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $13,400 | $600 | Not Implemented |
IC0134 # 08 Y:2007 | 08 | 2007 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,810 | $4,071 | Not Implemented |
IC0134 # 07 Y:2007 | 07 | 2007 | INSTALL OCCUPANCY SENSORS | $2,672 | $3,121 | Implemented |
IC0134 # 06 Y:2007 | 06 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,207 | $3,120 | Not Implemented |
IC0134 # 05 Y:2007 | 05 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,173 | $9,173 | Implemented |
IC0134 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,889 | $167,364 | Implemented |
IC0134 # 03 Y:2007 | 03 | 2007 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $14,325 | $0 | Not Implemented |
IC0134 # 02 Y:2007 | 02 | 2007 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $24,453 | $77,470 | Not Implemented |
IC0134 # 01 Y:2007 | 01 | 2007 | TURN OFF STEAM / HOT WATER LINES LEADING TO SPACE HEATING UNITS | $50,624 | $28,500 | Not Implemented |
IC0134 # 09 Y:2007 | 09 | 2007 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,787 | $0 | Implemented |
IC0134 # 10 Y:2007 | 10 | 2007 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $382 | $1,026 | Implemented |
UD0769 # 01 Y:2007 | 01 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $126,798 | $0 | Implemented |
UD0769 # 03 Y:2007 | 03 | 2007 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $63,509 | $110,000 | Implemented |
UD0769 # 07 Y:2007 | 07 | 2007 | TURN OFF EQUIPMENT WHEN NOT IN USE | $25,268 | $0 | Implemented |
UD0769 # 05 Y:2007 | 05 | 2007 | USE RADIANT HEATER FOR SPOT HEATING | $44,667 | $28,125 | Implemented |
UD0769 # 08 Y:2007 | 08 | 2007 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $23,200 | $400 | Implemented |
UD0769 # 02 Y:2007 | 02 | 2007 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $119,000 | $0 | Implemented |
UD0769 # 06 Y:2007 | 06 | 2007 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $39,200 | $130,000 | Implemented |
UD0769 # 04 Y:2007 | 04 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61,170 | $110,000 | Implemented |
UD0769 # 10 Y:2007 | 10 | 2007 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $10,000 | $25,000 | Not Implemented |