Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
118
matching recommendationsSIC | 3714 | Motor Vehicle Parts And Accessories |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0418 # 03 Y:2012 | 03 | 2012 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $151,000 | $60,000 | Not Implemented |
UM0418 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,257 | $7,500 | Not Implemented |
UM0418 # 01 Y:2012 | 01 | 2012 | USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST | $795,000 | $1,715,000 | Not Implemented |
UM0418 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,459 | $84,630 | Implemented |
UD0871 # 10 Y:2012 | 10 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,963 | $0 | Not Implemented |
UD0871 # 06 Y:2012 | 06 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,649 | $0 | Not Implemented |
UD0871 # 02 Y:2012 | 02 | 2012 | INSTALL OCCUPANCY SENSORS | $597 | $950 | Not Implemented |
UD0871 # 01 Y:2012 | 01 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,905 | $0 | Not Implemented |
UD0871 # 03 Y:2012 | 03 | 2012 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $488 | $0 | Not Implemented |
UD0871 # 13 Y:2012 | 13 | 2012 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,109 | $0 | Not Implemented |
UD0871 # 08 Y:2012 | 08 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $5,075 | $0 | Not Implemented |
UD0871 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,384 | $1,000 | Not Implemented |
UD0871 # 07 Y:2012 | 07 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,103 | $2,498 | Not Implemented |
UD0871 # 12 Y:2012 | 12 | 2012 | INSULATE BARE EQUIPMENT | $1,754 | $5,700 | Not Implemented |
UD0871 # 11 Y:2012 | 11 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,709 | $500 | Not Implemented |
UD0871 # 04 Y:2012 | 04 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $27,260 | $0 | Not Implemented |
UD0871 # 05 Y:2012 | 05 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,057 | $0 | Not Implemented |
UA3024 # 05 Y:2012 | 05 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $42,972 | $54,662 | Not Implemented |
UA3024 # 02 Y:2012 | 02 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $85,875 | $23,130 | Not Implemented |
UA3024 # 03 Y:2012 | 03 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $50,436 | $2,500 | Implemented |
UA3024 # 01 Y:2012 | 01 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $200,861 | $1,600 | Not Implemented |
UA3024 # 04 Y:2012 | 04 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,748 | $2,000 | Not Implemented |
UA3024 # 06 Y:2012 | 06 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $22,128 | $66,849 | Not Implemented |
IP0005 # 05 Y:2012 | 05 | 2012 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $16,542 | $37,000 | Not Implemented |
IP0005 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,112 | $0 | Not Implemented |