Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
50
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0167 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,700 | $250 | Implemented |
SD0167 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,973 | $6,500 | Implemented |
SD0167 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,304 | $0 | Implemented |
SD0167 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $840 | $0 | Implemented |
SD0167 # 06 Y:1997 | 06 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $51,824 | $0 | Not Implemented |
SD0167 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,601 | $24,427 | Implemented |
SD0167 # 08 Y:1997 | 08 | 1997 | BURN A LESS EXPENSIVE GRADE OF FUEL | $12,852 | $0 | Not Implemented |
SD0167 # 09 Y:1997 | 09 | 1997 | $6,790 | $0 | Not Implemented | |
SD0167 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,037 | $3,300 | Implemented |
SD0185 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $2,025 | Implemented |
SD0185 # 03 Y:1997 | 03 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $1,591 | $1,830 | Not Implemented |
SD0185 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $820 | $1,500 | Not Implemented |
SD0185 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $11,371 | $2,170 | Not Implemented |
SD0185 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $4,451 | $3,200 | Not Implemented |
SD0185 # 06 Y:1997 | 06 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $806 | $1,030 | Implemented |
SD0185 # 09 Y:1997 | 09 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,900 | $8,500 | Not Implemented |
SD0185 # 08 Y:1997 | 08 | 1997 | CONVERT TO LESS TOXIC HYDROCARBON CLEANERS | $53,325 | $0 | Implemented |
SD0185 # 07 Y:1997 | 07 | 1997 | USE ULTRASONIC CLEANING | $53,556 | $1,140 | Implemented |
SD0183 # 11 Y:1997 | 11 | 1997 | TREAT AND REUSE RINSE WATERS | $185 | $100 | Implemented |
SD0183 # 05 Y:1997 | 05 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $872 | $950 | Not Implemented |
SD0183 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $6,107 | $570 | Implemented |
SD0183 # 12 Y:1997 | 12 | 1997 | $162,000 | $250,000 | Not Implemented | |
SD0183 # 03 Y:1997 | 03 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $2,086 | $1,800 | Not Implemented |
SD0183 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,385 | $11,002 | Implemented |
SD0183 # 08 Y:1997 | 08 | 1997 | USE ULTRASONIC CLEANING | $11,564 | $1,140 | Not Implemented |