Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,491
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0354 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $48,587 | $63,488 | Implemented |
UF0354 # 02 Y:2004 | 02 | 2004 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $19,414 | $0 | Implemented |
UF0354 # 03 Y:2004 | 03 | 2004 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $18,795 | $62,620 | Not Implemented |
UF0354 # 04 Y:2004 | 04 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,169 | $745 | Not Implemented |
UF0354 # 05 Y:2004 | 05 | 2004 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $7,962 | $31,000 | Implemented |
UF0354 # 06 Y:2004 | 06 | 2004 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $6,140 | $779 | Not Implemented |
UF0354 # 07 Y:2004 | 07 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,543 | $0 | Implemented |
UF0354 # 08 Y:2004 | 08 | 2004 | ADD AREA LIGHTING SWITCHES | $2,354 | $11,495 | Not Implemented |
UF0354 # 09 Y:2004 | 09 | 2004 | RECYCLE FLUORESCENT LAMPS | $2,883 | $3,496 | Not Implemented |
SU0200 # 01 Y:2005 | 01 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $470 | $0 | Not Implemented |
SU0200 # 02 Y:2005 | 02 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,068 | $375 | Implemented |
SU0200 # 03 Y:2005 | 03 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,047 | $169 | Implemented |
SU0200 # 04 Y:2005 | 04 | 2005 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,439 | $1,636 | Implemented |
SU0200 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $327 | $374 | Implemented |
OK0697 # 01 Y:2004 | 01 | 2004 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $11,600 | $0 | Implemented |
OK0697 # 02 Y:2004 | 02 | 2004 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $2,218 | $100 | Not Implemented |
OK0697 # 03 Y:2004 | 03 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,032 | $1,400 | Not Implemented |
OK0697 # 04 Y:2004 | 04 | 2004 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $15,364 | $10,542 | Not Implemented |
OK0697 # 05 Y:2004 | 05 | 2004 | INSTALL OCCUPANCY SENSORS | $356 | $269 | Not Implemented |
OK0697 # 06 Y:2004 | 06 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $837 | $730 | Implemented |
OK0697 # 07 Y:2004 | 07 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $369 | $360 | Implemented |
OK0697 # 08 Y:2004 | 08 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,392 | $3,349 | Implemented |
OK0697 # 09 Y:2004 | 09 | 2004 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,054 | $18,900 | Not Implemented |
MI0095 # 01 Y:2004 | 01 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,778 | $600 | Not Implemented |
MI0095 # 02 Y:2004 | 02 | 2004 | TURN OFF EQUIPMENT WHEN NOT IN USE | $70,081 | $2,300 | Not Implemented |