Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,491
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LM0063 # 03 Y:2003 | 03 | 2003 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $80 | $30 | Implemented |
LM0063 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $828 | $232 | Implemented |
LM0063 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $68 | $85 | Not Implemented |
OK0666 # 01 Y:2003 | 01 | 2003 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $15,468 | $30,000 | Not Implemented |
OK0666 # 02 Y:2003 | 02 | 2003 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $18,000 | $0 | Not Implemented |
OK0666 # 03 Y:2003 | 03 | 2003 | INSTALL SET-BACK TIMERS | $11,925 | $1,200 | Not Implemented |
OK0666 # 04 Y:2003 | 04 | 2003 | INSTALL OCCUPANCY SENSORS | $543 | $404 | Not Implemented |
OK0666 # 05 Y:2003 | 05 | 2003 | INSTALL / REPAIR INSULATION ON STEAM LINES | $4,253 | $3,276 | Not Implemented |
OK0666 # 06 Y:2003 | 06 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $4,844 | $100 | Not Implemented |
OK0666 # 07 Y:2003 | 07 | 2003 | USE A DIFFERENT OR RECYCLED RAW MATERIAL | $136,157 | $28,500 | Not Implemented |
OK0666 # 08 Y:2003 | 08 | 2003 | IMPROVE SPACE COMFORT CONDITIONING | $58,240 | $20,000 | Not Implemented |
LE0152 # 01 Y:2003 | 01 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,205 | $0 | Implemented |
LE0152 # 02 Y:2003 | 02 | 2003 | USE CASCADE SYSTEM OF RECIRCULATING DURING COLD WEATHER TO AVOID SUB-COOLING | $1,150 | $1,000 | Not Implemented |
LE0152 # 03 Y:2003 | 03 | 2003 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $2,601 | $3,036 | Implemented |
LE0152 # 04 Y:2003 | 04 | 2003 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,998 | $10,129 | Not Implemented |
LE0152 # 05 Y:2003 | 05 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,965 | $0 | Not Implemented |
LE0152 # 06 Y:2003 | 06 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,694 | $1,312 | Implemented |
LE0152 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,329 | $57,678 | Implemented |
LM0054 # 01 Y:2003 | 01 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,854 | $1,545 | Implemented |
LM0054 # 02 Y:2003 | 02 | 2003 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,770 | $0 | Implemented |
LM0054 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,079 | $410 | Implemented |
LM0054 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,410 | $1,000 | Implemented |
LM0054 # 05 Y:2003 | 05 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $346 | $0 | Implemented |
LM0054 # 06 Y:2003 | 06 | 2003 | COVER OPEN TANKS | $3,464 | $420 | Implemented |
LM0054 # 07 Y:2003 | 07 | 2003 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,472 | $4,000 | Not Implemented |