Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsSIC | 372 | Aircraft And Parts |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0167 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,037 | $3,300 | Implemented |
SD0167 # 08 Y:1997 | 08 | 1997 | BURN A LESS EXPENSIVE GRADE OF FUEL | $12,852 | $0 | Not Implemented |
SD0167 # 09 Y:1997 | 09 | 1997 | MODIFY CURRENT INCENTIVE PROGRAM | $6,790 | $0 | Not Implemented |
SD0167 # 02 Y:1997 | 02 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,700 | $250 | Implemented |
SD0167 # 04 Y:1997 | 04 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,304 | $0 | Implemented |
SD0167 # 06 Y:1997 | 06 | 1997 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $51,824 | $0 | Not Implemented |
SD0167 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,601 | $24,427 | Implemented |
SD0167 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $840 | $0 | Implemented |
SD0167 # 03 Y:1997 | 03 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $3,973 | $6,500 | Implemented |
SD0185 # 04 Y:1997 | 04 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $820 | $1,500 | Not Implemented |
SD0185 # 05 Y:1997 | 05 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $710 | $2,025 | Implemented |
SD0185 # 08 Y:1997 | 08 | 1997 | CONVERT TO LESS TOXIC HYDROCARBON CLEANERS | $53,325 | $0 | Implemented |
SD0185 # 03 Y:1997 | 03 | 1997 | INSTALL TIMERS AND/OR THERMOSTATS | $1,591 | $1,830 | Not Implemented |
SD0185 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $4,451 | $3,200 | Not Implemented |
SD0185 # 01 Y:1997 | 01 | 1997 | USE OPTIMUM THICKNESS INSULATION | $11,371 | $2,170 | Not Implemented |
SD0185 # 06 Y:1997 | 06 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $806 | $1,030 | Implemented |
SD0185 # 09 Y:1997 | 09 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,900 | $8,500 | Not Implemented |
SD0185 # 07 Y:1997 | 07 | 1997 | USE ULTRASONIC CLEANING | $53,556 | $1,140 | Implemented |
SD0183 # 10 Y:1997 | 10 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,640 | $2,000 | Not Implemented |
SD0183 # 11 Y:1997 | 11 | 1997 | TREAT AND REUSE RINSE WATERS | $185 | $100 | Implemented |
SD0183 # 04 Y:1997 | 04 | 1997 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $915 | $650 | Implemented |
SD0183 # 07 Y:1997 | 07 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $7,155 | $9,085 | Implemented |
SD0183 # 01 Y:1997 | 01 | 1997 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $14,050 | $4,000 | Not Implemented |
SD0183 # 02 Y:1997 | 02 | 1997 | USE OPTIMUM THICKNESS INSULATION | $6,107 | $570 | Implemented |
SD0183 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,385 | $11,002 | Implemented |