Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3728 | Aircraft Parts And Equipment, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0602 # 06 Y:1996 | 06 | 1996 | USE PRECIPITATING AGENTS IN WASTE WATER TREATMENT THAT PRODUCE THE LEAST QUANTITY OF WASTE | $1,044 | $3,500 | Not Implemented |
GT0602 # 05 Y:1996 | 05 | 1996 | INCREASE USE OF AUTOMATION | $20,487 | $8,000 | Not Implemented |
GT0602 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,980 | $1,000 | Implemented |
GT0602 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $690 | $300 | Implemented |
GT0602 # 02 Y:1996 | 02 | 1996 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $1,330 | $500 | Not Implemented |
GT0602 # 01 Y:1996 | 01 | 1996 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $41,960 | $76,100 | Not Implemented |
AS0174 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,360 | $4,136 | Not Implemented |
AS0174 # 09 Y:1996 | 09 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,188 | $0 | Implemented |
AS0174 # 07 Y:1996 | 07 | 1996 | INSTALL OCCUPANCY SENSORS | $2,789 | $900 | Implemented |
AS0174 # 06 Y:1996 | 06 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $743 | $0 | Not Implemented |
AS0174 # 05 Y:1996 | 05 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,434 | $0 | Implemented |
AS0174 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,815 | $39,642 | Implemented |
AS0174 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $145 | $0 | Implemented |
AS0174 # 01 Y:1996 | 01 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $717 | $120 | Implemented |
AS0174 # 08 Y:1996 | 08 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $11,663 | $8,000 | Not Implemented |
OR0263 # 05 Y:1996 | 05 | 1996 | OPTIMIZE PLANT POWER FACTOR | $3,319 | $9,400 | Not Implemented |
OR0263 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,202 | $7,023 | Implemented |
OR0263 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $14,343 | $15,100 | Not Implemented |
OR0263 # 02 Y:1996 | 02 | 1996 | RECOVERY METALS FROM RINSE WATER(EVAP., ION EXCHANGE, RO, ELECTROLYSIS, ELECTRODIALYSIS) AND REUSE RINSE WATER | $69,830 | $183,000 | Not Implemented |
OR0263 # 01 Y:1996 | 01 | 1996 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $61,134 | $20,900 | Implemented |
OR0263 # 06 Y:1996 | 06 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $966 | $3,352 | Not Implemented |
OR0259 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,337 | $11,047 | Not Implemented |
OR0259 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $663 | $1,454 | Implemented |
OR0259 # 03 Y:1996 | 03 | 1996 | INSULATE BARE EQUIPMENT | $1,599 | $1,436 | Implemented |
OR0259 # 02 Y:1996 | 02 | 1996 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $584 | $0 | Implemented |