Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
281
matching recommendationsSIC | 374 | Railroad Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0152 # 12 Y:1992 | 12 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $827 | $2,800 | Implemented |
TN0353 # 01 Y:1988 | 01 | 1988 | KEEP LAMPS AND REFLECTORS CLEAN | $10,650 | $47,250 | Not Implemented |
TN0353 # 02 Y:1988 | 02 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,083 | $19,050 | Not Implemented |
TN0353 # 03 Y:1988 | 03 | 1988 | INSULATE BARE EQUIPMENT | $1,253 | $2,380 | Implemented |
TN0353 # 04 Y:1988 | 04 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,936 | $780 | Implemented |
TN0353 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,251 | $0 | Implemented |
TN0353 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $488 | $689 | Implemented |
OK0219 # 01 Y:1987 | 01 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,397 | $0 | Implemented |
OK0219 # 02 Y:1987 | 02 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $16,197 | $1,400 | Not Implemented |
OK0219 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $637 | $668 | Not Implemented |
UD0193 # 01 Y:1986 | 01 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $52,010 | $16,000 | Not Implemented |
UD0193 # 02 Y:1986 | 02 | 1986 | INSTALL STORM WINDOWS AND DOORS | $12,529 | $16,200 | Not Implemented |
UD0193 # 03 Y:1986 | 03 | 1986 | INSTALL SET-BACK TIMERS | $1,589 | $0 | Implemented |
UD0193 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,168 | $0 | Implemented |
UD0193 # 05 Y:1986 | 05 | 1986 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,134 | $21,000 | Implemented |
GT0242 # 01 Y:1985 | 01 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $780 | $20,000 | Not Implemented |
GT0242 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $380 | $175 | Not Implemented |
GT0242 # 03 Y:1985 | 03 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $238 | $373 | Not Implemented |
GT0242 # 04 Y:1985 | 04 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $500 | $0 | Not Implemented |
GT0242 # 05 Y:1985 | 05 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $243 | $251 | Not Implemented |
GT0242 # 06 Y:1985 | 06 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $910 | $50 | Not Implemented |
GT0242 # 07 Y:1985 | 07 | 1985 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,280 | $0 | Not Implemented |
GT0242 # 08 Y:1985 | 08 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $7,890 | $5,000 | Not Implemented |
TN0219 # 01 Y:1984 | 01 | 1984 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,852 | $3,879 | Not Implemented |
TN0219 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,107 | $600 | Not Implemented |