IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

27

matching recommendations
Reset
SIC 379 Miscellaneous Transportation Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0678 # 08 Y:1999 08 1999 COMBINE UTILITY METERS $7,560 $7,500 Not Implemented
GT0678 # 07 Y:1999 07 1999 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $44,185 $120,000 Not Implemented
GT0678 # 06 Y:1999 06 1999 TREAT AND REUSE EQUIPMENT CLEANING SOLUTIONS $35,980 $0 Implemented
GT0678 # 05 Y:1999 05 1999 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $8,447 $21,000 Not Implemented
GT0678 # 04 Y:1999 04 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,400 $0 Not Implemented
GT0678 # 03 Y:1999 03 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,880 $3,500 Not Implemented
GT0678 # 01 Y:1999 01 1999 METER WASTE WATER $4,925 $900 Implemented
GT0678 # 02 Y:1999 02 1999 REDUCE EXCESSIVE BOILER BLOWDOWN $920 $900 Not Implemented
IA0230 # 02 Y:1999 02 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,526 $0 Implemented
IA0230 # 10 Y:1999 10 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $3,710 $6,923 Not Implemented
IA0230 # 03 Y:1999 03 1999 INSTALL OCCUPANCY SENSORS $387 $798 Not Implemented
IA0230 # 04 Y:1999 04 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,152 $257 Implemented
IA0230 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $847 $1,105 Implemented
IA0230 # 06 Y:1999 06 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $900 $100 Not Implemented
IA0230 # 07 Y:1999 07 1999 REUSE / RECYCLE/ SELL RUBBER PRODUCTS $625 $50 Not Implemented
IA0230 # 08 Y:1999 08 1999 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $253 $50 Not Implemented
IA0230 # 09 Y:1999 09 1999 DISTILL CONTAMINATED SOLVENTS FOR REUSE $16,258 $7,853 Not Implemented
IA0230 # 01 Y:1999 01 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,917 $5,903 Implemented
IA0230 # 11 Y:1999 11 1999 MODIFY PROCESS TO REDUCE MATERIAL USE/COST $1,458 $50 Implemented
OR0339 # 07 Y:1999 07 1999 UPGRADE CONTROLS ON COMPRESSORS $1,508 $1,454 Implemented
OR0339 # 06 Y:1999 06 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $254 $1,000 Implemented
OR0339 # 05 Y:1999 05 1999 RECOVER WASTE HEAT FROM EQUIPMENT $730 $381 Not Implemented
OR0339 # 04 Y:1999 04 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $178 $0 Not Implemented
OR0339 # 03 Y:1999 03 1999 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $3,080 $13,800 Implemented
OR0339 # 02 Y:1999 02 1999 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $6,650 $24,750 Implemented