Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,872
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0230 # 14 Y:2012 | 14 | 2012 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,550 | $40 | Implemented |
MI0230 # 15 Y:2012 | 15 | 2012 | INSTALL OCCUPANCY SENSORS | $2,794 | $320 | Implemented |
AM0617 # 03 Y:2012 | 03 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,264 | $2,775 | Implemented |
AM0617 # 04 Y:2012 | 04 | 2012 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $2,146 | $0 | Implemented |
AM0617 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $2,056 | $1,562 | Implemented |
AM0617 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,871 | $64 | Implemented |
AM0617 # 07 Y:2012 | 07 | 2012 | RECYCLE WHITE WATER | $1,161 | $7,179 | Implemented |
AM0617 # 08 Y:2012 | 08 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $911 | $5,377 | Implemented |
AM0617 # 09 Y:2012 | 09 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $630 | $300 | Implemented |
LE0342 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,151 | $17,500 | Implemented |
LE0342 # 06 Y:2012 | 06 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $13,433 | $40,000 | Implemented |
LE0342 # 07 Y:2012 | 07 | 2012 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $24,116 | $60,000 | Implemented |
LE0342 # 08 Y:2012 | 08 | 2012 | REPAIR OR REPLACE STEAM TRAPS | $1,008 | $675 | Implemented |
LE0342 # 09 Y:2012 | 09 | 2012 | REPLACE BOILER | $225,837 | $230,000 | Implemented |
LE0342 # 13 Y:2012 | 13 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $72,444 | $410,000 | Implemented |
LE0342 # 14 Y:2012 | 14 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,722 | $85,000 | Implemented |
UD0850 # 03 Y:2012 | 03 | 2012 | KEEP LAMPS AND REFLECTORS CLEAN | $362 | $374 | Implemented |
UD0850 # 04 Y:2012 | 04 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,877 | $33,000 | Implemented |
UD0850 # 06 Y:2012 | 06 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $648 | $0 | Implemented |
UD0850 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $452 | $1,000 | Implemented |
UD0850 # 09 Y:2012 | 09 | 2012 | REDUCE VENTILATION AIR | $2,781 | $200 | Implemented |
UD0850 # 10 Y:2012 | 10 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,348 | $9,000 | Implemented |
UA0068 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $16,400 | $5,100 | Implemented |
UA0068 # 02 Y:2011 | 02 | 2011 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $15,438 | $13,988 | Implemented |
UA0068 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,451 | $46,341 | Implemented |