Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0390 # 04 Y:2001 | 04 | 2001 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,118 | $6,350 | Not Implemented |
WI0390 # 05 Y:2001 | 05 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $584 | $238 | Implemented |
WI0390 # 06 Y:2001 | 06 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $138 | $0 | Implemented |
WI0390 # 07 Y:2001 | 07 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $481 | $0 | Implemented |
WI0390 # 08 Y:2001 | 08 | 2001 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $397 | $0 | Implemented |
WI0390 # 09 Y:2001 | 09 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $161 | $640 | Implemented |
CO0481 # 01 Y:2001 | 01 | 2001 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,690 | $2,000 | Not Implemented |
CO0481 # 02 Y:2001 | 02 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,370 | $0 | Implemented |
CO0481 # 03 Y:2001 | 03 | 2001 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,230 | $880 | Implemented |
CO0481 # 04 Y:2001 | 04 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,030 | $0 | Implemented |
CO0481 # 05 Y:2001 | 05 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $870 | $130 | Implemented |
CO0481 # 06 Y:2001 | 06 | 2001 | USE OPTIMUM TEMPERATURE | $820 | $2,330 | Implemented |
CO0481 # 07 Y:2001 | 07 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $480 | $30 | Not Implemented |
CO0481 # 08 Y:2001 | 08 | 2001 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $300 | $130 | Implemented |
CO0481 # 09 Y:2001 | 09 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $160 | $0 | Implemented |
SD0268 # 01 Y:2001 | 01 | 2001 | MOVE BOILER TO MORE EFFICIENT LOCATION | $40,607 | $10,000 | Not Implemented |
SD0268 # 02 Y:2001 | 02 | 2001 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $92,095 | $50,000 | Not Implemented |
SD0268 # 03 Y:2001 | 03 | 2001 | TURN OFF EQUIPMENT WHEN NOT IN USE | $26,840 | $4,000 | Not Implemented |
SD0268 # 04 Y:2001 | 04 | 2001 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $7,953 | $16,000 | Not Implemented |
SD0268 # 05 Y:2001 | 05 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,448 | $2,060 | Not Implemented |
SD0268 # 06 Y:2001 | 06 | 2001 | MOVE BOILER TO MORE EFFICIENT LOCATION | $10,321 | $17,000 | Not Implemented |
SD0268 # 07 Y:2001 | 07 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $7,700 | $15,000 | Not Implemented |
SD0268 # 08 Y:2001 | 08 | 2001 | AUTOMATE FINISHING PROCESS | $145,400 | $150,000 | Implemented |
SD0268 # 09 Y:2001 | 09 | 2001 | AUTOMATE FINISHING PROCESS | $77,200 | $80,000 | Implemented |
SD0268 # 10 Y:2001 | 10 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $793 | $0 | Not Implemented |