Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0259 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,865 | $2,831 | Implemented |
UF0259 # 02 Y:2000 | 02 | 2000 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $5,242 | $12,014 | Not Implemented |
UF0259 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,732 | $7,400 | Implemented |
UF0259 # 04 Y:2000 | 04 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,323 | $50 | Implemented |
UF0259 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,597 | $460 | Implemented |
UF0259 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,740 | $0 | Implemented |
UF0259 # 07 Y:2000 | 07 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $835 | $1,500 | Not Implemented |
UF0259 # 08 Y:2000 | 08 | 2000 | INSTALL OCCUPANCY SENSORS | $481 | $834 | Implemented |
UF0259 # 09 Y:2000 | 09 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $704 | $600 | Implemented |
UF0259 # 10 Y:2000 | 10 | 2000 | METER WASTE WATER | $2,940 | $1,500 | Implemented |
UF0259 # 11 Y:2000 | 11 | 2000 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,874 | $3,721 | Not Implemented |
UF0259 # 12 Y:2000 | 12 | 2000 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $67,200 | $84,000 | Not Implemented |
NV0167 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,639 | $200 | Implemented |
NV0167 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $414 | $50 | Implemented |
NV0167 # 03 Y:2000 | 03 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $229 | $0 | Not Implemented |
NV0167 # 04 Y:2000 | 04 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $3,315 | $680 | Not Implemented |
KU0548 # 01 Y:2000 | 01 | 2000 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $13,917 | $0 | n/a |
KU0548 # 02 Y:2000 | 02 | 2000 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $6,154 | $11,500 | n/a |
KU0548 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,963 | $1,505 | n/a |
KU0548 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,604 | $40 | n/a |
KU0548 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,422 | $1,050 | n/a |
KU0548 # 06 Y:2000 | 06 | 2000 | MINIMIZE WATER USAGE | $4,075 | $4,075 | n/a |
DS0174 # 01 Y:2000 | 01 | 2000 | REDUCE VENTILATION AIR | $8,393 | $4,500 | Implemented |
DS0174 # 02 Y:2000 | 02 | 2000 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $403 | $238 | Implemented |
DS0174 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $300 | $540 | Implemented |