Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0260 # 01 Y:1999 | 01 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,561 | $11,150 | Not Implemented |
ME0260 # 02 Y:1999 | 02 | 1999 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $3,589 | $2,480 | Not Implemented |
ME0260 # 03 Y:1999 | 03 | 1999 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,693 | $3,398 | Not Implemented |
ME0260 # 04 Y:1999 | 04 | 1999 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $585 | $171 | Implemented |
ME0260 # 05 Y:1999 | 05 | 1999 | COMBINE UTILITY METERS | $657 | $720 | Not Implemented |
ME0260 # 06 Y:1999 | 06 | 1999 | COMBINE UTILITY METERS | $456 | $230 | Not Implemented |
ME0260 # 07 Y:1999 | 07 | 1999 | RECOVER AND REUSE COOLING WATER | $352 | $350 | Not Implemented |
SF0159 # 01 Y:1999 | 01 | 1999 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,720 | $0 | Implemented |
SF0159 # 02 Y:1999 | 02 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,207 | $1,400 | Implemented |
SF0159 # 03 Y:1999 | 03 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,405 | $1,100 | Not Implemented |
SF0159 # 04 Y:1999 | 04 | 1999 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,977 | $0 | Implemented |
SF0159 # 05 Y:1999 | 05 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $977 | $1,439 | Implemented |
SF0159 # 06 Y:1999 | 06 | 1999 | OPTIMIZE PLANT POWER FACTOR | $3,156 | $5,517 | Implemented |
SF0159 # 07 Y:1999 | 07 | 1999 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,452 | $2,550 | Implemented |
SF0159 # 08 Y:1999 | 08 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,589 | $21,750 | Implemented |
SF0159 # 09 Y:1999 | 09 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,339 | $1,339 | Implemented |
SF0159 # 10 Y:1999 | 10 | 1999 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $2,606 | $0 | Not Implemented |
SF0159 # 11 Y:1999 | 11 | 1999 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,850 | $250 | Not Implemented |
AS0242 # 01 Y:1999 | 01 | 1999 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $297 | $398 | Implemented |
AS0242 # 02 Y:1999 | 02 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $551 | Implemented |
AS0242 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $1,628 | $2,550 | Not Implemented |
AS0242 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,416 | $15,077 | Not Implemented |
AS0242 # 05 Y:1999 | 05 | 1999 | USE OPTIMUM THICKNESS INSULATION | $3,847 | $383 | Implemented |
AS0242 # 06 Y:1999 | 06 | 1999 | TURN OFF EQUIPMENT WHEN NOT IN USE | $76 | $45 | Not Implemented |
AS0242 # 07 Y:1999 | 07 | 1999 | SEPARATE TREATMENTS FOR EACH TYPE OF SOLUTION AND RECYCLE | $890 | $120 | Not Implemented |