IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,140

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0179 # 01 Y:1997 01 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $1,524 $352 Not Implemented
UF0179 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,163 $34,581 Not Implemented
UF0179 # 03 Y:1997 03 1997 INSTALL OCCUPANCY SENSORS $570 $820 Not Implemented
UF0179 # 04 Y:1997 04 1997 INSTALL HEAT PIPES / RAISE COOLING SETPOINT $2,876 $3,700 Not Implemented
UF0179 # 05 Y:1997 05 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $3,421 $8,860 Not Implemented
UF0179 # 06 Y:1997 06 1997 USE A DIFFERENT OR RECYCLED RAW MATERIAL $24,578 $0 Not Implemented
UF0179 # 07 Y:1997 07 1997 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $3,062 $0 Not Implemented
CO0388 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,648 $3,958 Not Implemented
CO0388 # 02 Y:1997 02 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $970 $400 Implemented
CO0388 # 03 Y:1997 03 1997 RECOVER WASTE HEAT FROM EQUIPMENT $390 $930 Implemented
CO0388 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $390 $330 Implemented
CO0388 # 05 Y:1997 05 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $260 $500 Not Implemented
CO0388 # 06 Y:1997 06 1997 UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID $3,300 $11,100 Not Implemented
CO0388 # 07 Y:1997 07 1997 BURN WASTE OIL FOR HEAT $830 $3,320 Not Implemented
CO0388 # 08 Y:1997 08 1997 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $1,180 $1,500 Not Implemented
CO0388 # 09 Y:1997 09 1997 ELIMINATE/REDUCE REDUNDANT INSPECTIONS $5,910 $14,000 Implemented
WV0117 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,328 $484 Implemented
WV0117 # 02 Y:1997 02 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,793 $3,114 Implemented
WV0117 # 03 Y:1997 03 1997 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $63 $30 Implemented
WV0117 # 04 Y:1997 04 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,037 $417 Not Implemented
WV0117 # 05 Y:1997 05 1997 USE SYNTHETIC LUBRICANT $907 $615 Not Implemented
WV0117 # 06 Y:1997 06 1997 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,795 $200 Implemented
WV0117 # 07 Y:1997 07 1997 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,252 $1,175 Not Implemented
WV0117 # 08 Y:1997 08 1997 RECOVER WASTE HEAT FROM EQUIPMENT $4,386 $1,000 Not Implemented
WV0117 # 09 Y:1997 09 1997 DIRECT WARMEST AIR TO COMBUSTION INTAKE $2,683 $3,740 Not Implemented