Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
110
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0325 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,946 | $6,396 | Implemented |
LE0325 # 06 Y:2011 | 06 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $15,840 | Not Implemented |
LE0325 # 01 Y:2011 | 01 | 2011 | USE HEAT PUMP FOR SPACE CONDITIONING | $148,547 | $900,000 | Not Implemented |
LE0325 # 04 Y:2011 | 04 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,438 | $0 | Not Implemented |
LE0311 # 06 Y:2011 | 06 | 2011 | INSTALL OCCUPANCY SENSORS | $659 | $1,875 | Implemented |
LE0311 # 03 Y:2011 | 03 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $676 | $1,500 | Not Implemented |
LE0311 # 02 Y:2011 | 02 | 2011 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,806 | $28,000 | Not Implemented |
LE0311 # 01 Y:2011 | 01 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $40,488 | $240 | Implemented |
LE0311 # 08 Y:2011 | 08 | 2011 | INSTALL TIMERS AND/OR THERMOSTATS | $226 | $60 | Implemented |
LE0311 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $458 | $0 | Implemented |
LE0311 # 05 Y:2011 | 05 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,691 | $5,441 | Implemented |
LE0311 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $356 | $0 | Not Implemented |
WV0389 # 09 Y:2009 | 09 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,740 | $600 | Implemented |
WV0389 # 08 Y:2009 | 08 | 2009 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,947 | $290 | Not Implemented |
WV0389 # 14 Y:2009 | 14 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $526 | $0 | Not Implemented |
WV0389 # 05 Y:2009 | 05 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,461 | $1,740 | Not Implemented |
WV0389 # 01 Y:2009 | 01 | 2009 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $5,844 | $1,000 | Implemented |
WV0389 # 04 Y:2009 | 04 | 2009 | DEVELOP A REPAIR/REPLACE POLICY | $4,703 | $662 | Implemented |
WV0389 # 11 Y:2009 | 11 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,462 | $2,860 | Implemented |
WV0389 # 12 Y:2009 | 12 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,327 | $0 | Implemented |
WV0389 # 10 Y:2009 | 10 | 2009 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $1,613 | $6,810 | Not Implemented |
WV0389 # 07 Y:2009 | 07 | 2009 | USE OPTIMUM THICKNESS INSULATION | $2,517 | $960 | Implemented |
WV0389 # 06 Y:2009 | 06 | 2009 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $3,065 | $8,080 | Not Implemented |
WV0389 # 03 Y:2009 | 03 | 2009 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $4,832 | $4,053 | Not Implemented |
WV0389 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,876 | $5,376 | Not Implemented |