Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
94
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TT0208 # 05 Y:2018 | 05 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,732 | $2,250 | Not Implemented |
TT0208 # 04 Y:2018 | 04 | 2018 | INSTALL OCCUPANCY SENSORS | $3,716 | $2,030 | Not Implemented |
TT0208 # 06 Y:2018 | 06 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $439 | $600 | Not Implemented |
TT0208 # 01 Y:2018 | 01 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $24,976 | $33,750 | Not Implemented |
TT0207 # 05 Y:2018 | 05 | 2018 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $618 | $1,770 | Not Implemented |
TT0207 # 03 Y:2018 | 03 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,589 | $2,450 | Implemented |
TT0207 # 04 Y:2018 | 04 | 2018 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,313 | $250 | Not Implemented |
TT0207 # 02 Y:2018 | 02 | 2018 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,922 | $9,020 | Not Implemented |
TT0207 # 01 Y:2018 | 01 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,878 | $41,788 | Implemented |
TT0179 # 01 Y:2016 | 01 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,880 | $54,314 | Not Implemented |
TT0179 # 08 Y:2016 | 08 | 2016 | DEVELOP A REPAIR/REPLACE POLICY | $415 | $1,064 | Not Implemented |
TT0179 # 10 Y:2016 | 10 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $167 | $195 | Not Implemented |
TT0179 # 09 Y:2016 | 09 | 2016 | INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS | $319 | $421 | Not Implemented |
TT0179 # 05 Y:2016 | 05 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,568 | $4,800 | Implemented |
TT0179 # 07 Y:2016 | 07 | 2016 | UPGRADE CONTROLS ON COMPRESSORS | $802 | $2,000 | Not Implemented |
TT0179 # 06 Y:2016 | 06 | 2016 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,325 | $0 | Not Implemented |
TT0179 # 02 Y:2016 | 02 | 2016 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,035 | $0 | Implemented |
TT0179 # 03 Y:2016 | 03 | 2016 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $5,391 | $0 | Implemented |
TT0179 # 04 Y:2016 | 04 | 2016 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,217 | $0 | Implemented |
AR0166 # 08 Y:1999 | 08 | 1999 | INSTALL EQUIPMENT TO MOVE PRODUCT | $78,658 | $7,500 | Not Implemented |
AR0166 # 07 Y:1999 | 07 | 1999 | USE A RAG RECYCLE SERVICE | $35,201 | $0 | Not Implemented |
AR0166 # 06 Y:1999 | 06 | 1999 | OVERLAP CUSTODIAL SERVICES WITH NORMAL DAY HOURS | $11,974 | $0 | Not Implemented |
AR0166 # 05 Y:1999 | 05 | 1999 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,110 | $201 | Not Implemented |
AR0166 # 04 Y:1999 | 04 | 1999 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,702 | $4,980 | Implemented |
AR0166 # 03 Y:1999 | 03 | 1999 | INSTALL OCCUPANCY SENSORS | $23,676 | $38,630 | Implemented |