Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,140

matching recommendations
Reset
SIC 38 Instruments And Related Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
DL0067 # 07 Y:2011 07 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $16,400 $1,200 Not Implemented
DL0067 # 08 Y:2011 08 2011 USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR $19,150 $13,200 Not Implemented
MA0667 # 01 Y:2011 01 2011 REDUCE VENTILATION AIR $45,912 $17,705 Not Implemented
MA0667 # 02 Y:2011 02 2011 IMPROVE COMBUSTION CONTROL CAPABILITY $31,118 $100,000 Not Implemented
MA0667 # 03 Y:2011 03 2011 MODERATE COOLING TOWER OUTLET TEMPERATURE $11,694 $10,590 Implemented
MA0667 # 04 Y:2011 04 2011 REDUCE VENTILATION AIR $8,118 $0 Implemented
MA0667 # 05 Y:2011 05 2011 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS $3,023 $250 Implemented
MA0667 # 06 Y:2011 06 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,246 $3,000 Not Implemented
MA0667 # 07 Y:2011 07 2011 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $5,047 $17,500 Not Implemented
MA0667 # 08 Y:2011 08 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,129 $6,340 Not Implemented
MA0667 # 09 Y:2011 09 2011 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,515 $4,000 Not Implemented
MA0667 # 10 Y:2011 10 2011 INSTALL AUTOMATIC STACK DAMPER $729 $180 Implemented
MA0667 # 11 Y:2011 11 2011 INSULATE BARE EQUIPMENT $525 $550 Not Implemented
MA0667 # 12 Y:2011 12 2011 INSULATE BARE EQUIPMENT $98 $201 Not Implemented
LE0311 # 01 Y:2011 01 2011 INSTALL TIMERS AND/OR THERMOSTATS $40,488 $240 Implemented
LE0311 # 02 Y:2011 02 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $7,806 $28,000 Not Implemented
LE0311 # 03 Y:2011 03 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $676 $1,500 Not Implemented
LE0311 # 04 Y:2011 04 2011 INSTALL OCCUPANCY SENSORS $356 $0 Not Implemented
LE0311 # 05 Y:2011 05 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,691 $5,441 Implemented
LE0311 # 06 Y:2011 06 2011 INSTALL OCCUPANCY SENSORS $659 $1,875 Implemented
LE0311 # 07 Y:2011 07 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $458 $0 Implemented
LE0311 # 08 Y:2011 08 2011 INSTALL TIMERS AND/OR THERMOSTATS $226 $60 Implemented
AM0588 # 01 Y:2010 01 2010 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $13,390 $0 Implemented
AM0588 # 02 Y:2010 02 2010 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $19,580 $500 Implemented
AM0588 # 03 Y:2010 03 2010 PAY UTILITY BILLS ON TIME $2,160 $0 Implemented