Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,140
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0302 # 01 Y:2006 | 01 | 2006 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,774 | $0 | Not Implemented |
BD0302 # 02 Y:2006 | 02 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,381 | $0 | Implemented |
BD0302 # 03 Y:2006 | 03 | 2006 | USE RADIANT HEATER FOR SPOT HEATING | $1,699 | $5,000 | Not Implemented |
BD0302 # 04 Y:2006 | 04 | 2006 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,130 | $0 | Implemented |
BD0302 # 05 Y:2006 | 05 | 2006 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $848 | $260 | Not Implemented |
BD0302 # 06 Y:2006 | 06 | 2006 | INSTALL OCCUPANCY SENSORS | $835 | $1,050 | Not Implemented |
BD0302 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1 | $0 | Not Implemented |
BD0302 # 08 Y:2006 | 08 | 2006 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,195 | $1,550 | Not Implemented |
BD0302 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $384 | $0 | Implemented |
BD0302 # 10 Y:2006 | 10 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $344 | $500 | Implemented |
BD0302 # 11 Y:2006 | 11 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $304 | $2,550 | Not Implemented |
BD0302 # 12 Y:2006 | 12 | 2006 | MINIMIZE WATER USAGE | $2,375 | $1,725 | Not Implemented |
AM0503 # 01 Y:2006 | 01 | 2006 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $16,230 | $33,000 | Not Implemented |
AM0503 # 02 Y:2006 | 02 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,600 | $500 | Implemented |
AM0503 # 03 Y:2006 | 03 | 2006 | OPTIMIZE PLANT POWER FACTOR | $6,550 | $17,100 | Not Implemented |
AM0503 # 04 Y:2006 | 04 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,320 | $300 | Implemented |
AM0503 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $930 | $27 | Implemented |
AM0503 # 06 Y:2006 | 06 | 2006 | REUSE RAGS UNTIL COMPLETELY SOILED | $880 | $0 | Not Implemented |
AM0503 # 07 Y:2006 | 07 | 2006 | USE SYNTHETIC LUBRICANT | $256 | $0 | Not Implemented |
MA0589 # 01 Y:2006 | 01 | 2006 | BURN A LESS EXPENSIVE GRADE OF FUEL | $29,215 | $95,420 | Not Implemented |
MA0589 # 02 Y:2006 | 02 | 2006 | USE MINIMUM SAFE OVEN VENTILATION | $13,600 | $1,600 | Not Implemented |
MA0589 # 03 Y:2006 | 03 | 2006 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $3,300 | $4,000 | Implemented |
MA0589 # 04 Y:2006 | 04 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,608 | $10,890 | Not Implemented |
MA0589 # 05 Y:2006 | 05 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,311 | $3,565 | Implemented |
MA0589 # 06 Y:2006 | 06 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $1,951 | $400 | Implemented |