Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
473
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0325 # 01 Y:2003 | 01 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $88,041 | $300,075 | Not Implemented |
SD0325 # 02 Y:2003 | 02 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $71,754 | $0 | Implemented |
SD0325 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $53,956 | $32,725 | Implemented |
SD0325 # 04 Y:2003 | 04 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $37,849 | $2,000 | Implemented |
SD0325 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $36,071 | $1,000 | Implemented |
SD0325 # 06 Y:2003 | 06 | 2003 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $14,542 | $0 | Not Implemented |
SD0325 # 07 Y:2003 | 07 | 2003 | INSTALL SKYLIGHTS | $9,297 | $18,000 | Not Implemented |
SD0325 # 08 Y:2003 | 08 | 2003 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,279 | $1,410 | Not Implemented |
SD0314 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $173,249 | $120,000 | Not Implemented |
SD0314 # 02 Y:2003 | 02 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $35,689 | $50,000 | Not Implemented |
SD0314 # 03 Y:2003 | 03 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $29,440 | $17,250 | Not Implemented |
SD0314 # 04 Y:2003 | 04 | 2003 | REDESIGN PROCESS | $28,616 | $11,700 | Not Implemented |
SD0314 # 05 Y:2003 | 05 | 2003 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $26,207 | $48,175 | Not Implemented |
SD0314 # 06 Y:2003 | 06 | 2003 | INSTALL SPECTRAL REFLECTORS / DELAMP | $15,709 | $33,075 | Not Implemented |
SD0314 # 07 Y:2003 | 07 | 2003 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $9,389 | $0 | Implemented |
SD0314 # 08 Y:2003 | 08 | 2003 | INSTALL OCCUPANCY SENSORS | $9,097 | $1,000 | Implemented |
SD0314 # 09 Y:2003 | 09 | 2003 | INSULATE BARE EQUIPMENT | $2,478 | $450 | Not Implemented |
SD0314 # 10 Y:2003 | 10 | 2003 | INSULATE BARE EQUIPMENT | $242 | $920 | Implemented |
SD0314 # 11 Y:2003 | 11 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $598 | $0 | Not Implemented |
SD0314 # 12 Y:2003 | 12 | 2003 | AUTOMATE FINISHING PROCESS | $6,678 | $3,294 | Not Implemented |
SD0311 # 01 Y:2003 | 01 | 2003 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $10,146 | $19,000 | Not Implemented |
SD0311 # 02 Y:2003 | 02 | 2003 | USE PHOTOCELL CONTROLS | $3,064 | $2,000 | Implemented |
SD0311 # 03 Y:2003 | 03 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $501 | $0 | Implemented |
SD0311 # 04 Y:2003 | 04 | 2003 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,622 | $5,000 | Implemented |
SD0311 # 05 Y:2003 | 05 | 2003 | MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE | $31,104 | $0 | Not Implemented |