Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
52
matching recommendationsSIC | 38 | Instruments And Related Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0226 # 03 Y:2024 | 03 | 2024 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,027 | $9,016 | n/a |
WM0226 # 02 Y:2024 | 02 | 2024 | INSTALL OCCUPANCY SENSORS | $7,290 | $0 | n/a |
WM0226 # 06 Y:2024 | 06 | 2024 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $251 | $460 | n/a |
WM0226 # 05 Y:2024 | 05 | 2024 | INSTALL TIMERS AND/OR THERMOSTATS | $835 | $198 | n/a |
WM0226 # 01 Y:2024 | 01 | 2024 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $31,974 | $246,400 | n/a |
WM0226 # 04 Y:2024 | 04 | 2024 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $5,832 | $2,000 | n/a |
WM0078 # 02 Y:2015 | 02 | 2015 | USE SYNTHETIC LUBRICANT | $14,981 | $4,505 | Not Implemented |
WM0078 # 03 Y:2015 | 03 | 2015 | OPTIMIZE PLANT POWER FACTOR | $11,162 | $18,000 | Not Implemented |
WM0078 # 09 Y:2015 | 09 | 2015 | USE PHOTOCELL CONTROLS | $2,082 | $2,816 | Not Implemented |
WM0078 # 11 Y:2015 | 11 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,156 | $300 | Not Implemented |
WM0078 # 12 Y:2015 | 12 | 2015 | INSTALL OCCUPANCY SENSORS | $1,006 | $1,500 | Not Implemented |
WM0078 # 05 Y:2015 | 05 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,459 | $11,985 | Not Implemented |
WM0078 # 01 Y:2015 | 01 | 2015 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $31,723 | $105,982 | Not Implemented |
WM0078 # 04 Y:2015 | 04 | 2015 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $10,083 | $3,000 | Not Implemented |
WM0078 # 10 Y:2015 | 10 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,824 | $1,300 | Not Implemented |
WM0078 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,708 | $400 | Not Implemented |
WM0078 # 06 Y:2015 | 06 | 2015 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,749 | $8,000 | Not Implemented |
WM0078 # 08 Y:2015 | 08 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,724 | $2,584 | Not Implemented |
WM0022 # 01 Y:2013 | 01 | 2013 | OPTIMIZE PLANT POWER FACTOR | $12,280 | $30,697 | Not Implemented |
WM0022 # 03 Y:2013 | 03 | 2013 | INSULATE BARE EQUIPMENT | $2,744 | $2,303 | Implemented |
WM0022 # 02 Y:2013 | 02 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,779 | $6,480 | Implemented |
IC0166 # 08 Y:2009 | 08 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $659 | $0 | Not Implemented |
IC0166 # 06 Y:2009 | 06 | 2009 | INSTALL TIMERS AND/OR THERMOSTATS | $134 | $0 | Implemented |
IC0166 # 05 Y:2009 | 05 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $84 | $345 | Implemented |
IC0166 # 03 Y:2009 | 03 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $757 | $136 | Not Implemented |