Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
276
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0058 # 15 Y:1993 | 15 | 1993 | INSTALL SET-BACK TIMERS | $2,448 | $9,280 | Not Implemented |
SD0058 # 16 Y:1993 | 16 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,403 | $455 | Not Implemented |
SD0058 # 17 Y:1993 | 17 | 1993 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $34,305 | $0 | Implemented |
SD0058 # 18 Y:1993 | 18 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $3,185 | $300 | Implemented |
SD0046 # 01 Y:1993 | 01 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $40 | $98 | Not Implemented |
SD0046 # 02 Y:1993 | 02 | 1993 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $418 | $60 | Not Implemented |
SD0046 # 03 Y:1993 | 03 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $10,111 | $600 | Not Implemented |
SD0046 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,768 | $0 | Not Implemented |
SD0046 # 05 Y:1993 | 05 | 1993 | INSTALL SPECTRAL REFLECTORS / DELAMP | $6,470 | $5,480 | Not Implemented |
SD0046 # 06 Y:1993 | 06 | 1993 | INSTALL SET-BACK TIMERS | $1,223 | $2,680 | Not Implemented |
SD0046 # 07 Y:1993 | 07 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $719 | $3,300 | Not Implemented |
SD0046 # 08 Y:1993 | 08 | 1993 | USE PHOTOCELL CONTROLS | $473 | $115 | Not Implemented |
SD0024 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,191 | $1,920 | Implemented |
SD0024 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $517 | $50 | Implemented |
SD0024 # 03 Y:1992 | 03 | 1992 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $176 | $0 | Implemented |
SD0024 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $1,581 | $3,000 | Implemented |
SD0024 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $358 | $0 | Implemented |
SD0024 # 06 Y:1992 | 06 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $3,234 | $5,640 | Implemented |
SD0024 # 07 Y:1992 | 07 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,811 | $9,000 | Implemented |
SD0020 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $102 | $78 | Not Implemented |
SD0020 # 02 Y:1992 | 02 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $3,916 | $1,632 | Not Implemented |
SD0020 # 03 Y:1992 | 03 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $294 | $100 | Not Implemented |
SD0020 # 04 Y:1992 | 04 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $176 | $100 | Not Implemented |
SD0020 # 05 Y:1992 | 05 | 1992 | INSTALL SET-BACK TIMERS | $3,655 | $11,550 | Not Implemented |
SD0020 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $791 | $666 | Not Implemented |