Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
91
matching recommendationsSIC | 382 | Measuring And Controlling Devices |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0753 # 05 Y:2015 | 05 | 2015 | INSULATE BARE EQUIPMENT | $1,226 | $1,400 | Implemented |
MA0753 # 06 Y:2015 | 06 | 2015 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $842 | $2,152 | Not Implemented |
MA0708 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,828 | $3,200 | Implemented |
MA0708 # 03 Y:2013 | 03 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,140 | $400 | Implemented |
MA0708 # 02 Y:2013 | 02 | 2013 | REDUCE VENTILATION AIR | $3,194 | $7,450 | Not Implemented |
MA0708 # 01 Y:2013 | 01 | 2013 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $4,752 | $30,000 | Not Implemented |
MA0704 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $601 | $2,200 | Not Implemented |
MA0704 # 05 Y:2013 | 05 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,765 | $500 | Not Implemented |
MA0704 # 04 Y:2013 | 04 | 2013 | REDUCE VENTILATION AIR | $2,055 | $5,900 | Implemented |
MA0704 # 03 Y:2013 | 03 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,329 | $5,680 | Not Implemented |
MA0704 # 02 Y:2013 | 02 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,747 | $9,100 | Not Implemented |
MA0704 # 01 Y:2013 | 01 | 2013 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $10,351 | $200 | Not Implemented |
MA0680 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $630 | $2,895 | Implemented |
MA0680 # 04 Y:2011 | 04 | 2011 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $265 | $2,000 | Not Implemented |
MA0680 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $151 | $0 | Implemented |
MA0680 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $3,229 | $2,895 | Implemented |
MA0680 # 01 Y:2011 | 01 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,371 | $45,123 | Implemented |
MA0667 # 02 Y:2011 | 02 | 2011 | IMPROVE COMBUSTION CONTROL CAPABILITY | $31,118 | $100,000 | Not Implemented |
MA0667 # 07 Y:2011 | 07 | 2011 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $5,047 | $17,500 | Not Implemented |
MA0667 # 09 Y:2011 | 09 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $1,515 | $4,000 | Not Implemented |
MA0667 # 01 Y:2011 | 01 | 2011 | REDUCE VENTILATION AIR | $45,912 | $17,705 | Not Implemented |
MA0667 # 12 Y:2011 | 12 | 2011 | INSULATE BARE EQUIPMENT | $98 | $201 | Not Implemented |
MA0667 # 10 Y:2011 | 10 | 2011 | INSTALL AUTOMATIC STACK DAMPER | $729 | $180 | Implemented |
MA0667 # 11 Y:2011 | 11 | 2011 | INSULATE BARE EQUIPMENT | $525 | $550 | Not Implemented |
MA0667 # 04 Y:2011 | 04 | 2011 | REDUCE VENTILATION AIR | $8,118 | $0 | Implemented |