Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
209
matching recommendationsSIC | 3823 | Process Control Instruments |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0868 # 11 Y:2013 | 11 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,457 | $13,371 | Implemented |
UD0850 # 03 Y:2012 | 03 | 2012 | KEEP LAMPS AND REFLECTORS CLEAN | $362 | $374 | Implemented |
UD0850 # 04 Y:2012 | 04 | 2012 | UPGRADE CONTROLS ON COMPRESSORS | $15,877 | $33,000 | Implemented |
UD0850 # 07 Y:2012 | 07 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $452 | $1,000 | Implemented |
UD0850 # 06 Y:2012 | 06 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $648 | $0 | Implemented |
UD0850 # 09 Y:2012 | 09 | 2012 | REDUCE VENTILATION AIR | $2,781 | $200 | Implemented |
UD0850 # 10 Y:2012 | 10 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $2,348 | $9,000 | Implemented |
MA0680 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $3,229 | $2,895 | Implemented |
MA0680 # 01 Y:2011 | 01 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $5,371 | $45,123 | Implemented |
MA0680 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $630 | $2,895 | Implemented |
MA0680 # 05 Y:2011 | 05 | 2011 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $151 | $0 | Implemented |
UF0427 # 02 Y:2009 | 02 | 2009 | INSTALL OCCUPANCY SENSORS | $519 | $837 | Implemented |
UF0427 # 09 Y:2009 | 09 | 2009 | PAY UTILITY BILLS ON TIME | $477 | $0 | Implemented |
UF0427 # 07 Y:2009 | 07 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $677 | $800 | Implemented |
UF0427 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,625 | $0 | Implemented |
UF0427 # 01 Y:2009 | 01 | 2009 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $587 | $0 | Implemented |
SU0283 # 03 Y:2009 | 03 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,551 | $260 | Implemented |
SU0283 # 04 Y:2009 | 04 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,768 | $182 | Implemented |
SU0283 # 05 Y:2009 | 05 | 2009 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $715 | $563 | Implemented |
UD0796 # 04 Y:2009 | 04 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $4,088 | $0 | Implemented |
UD0796 # 03 Y:2009 | 03 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,237 | $0 | Implemented |
UD0796 # 02 Y:2009 | 02 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $9,992 | $1,525 | Implemented |
UD0796 # 06 Y:2009 | 06 | 2009 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,734 | $500 | Implemented |
UD0796 # 01 Y:2009 | 01 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $17,000 | $4,900 | Implemented |
UD0796 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $935 | $2,115 | Implemented |